FACTORY-INSTALLED OPTIONS
SINGLE INPUT ELECTRONIC ENTHALPY ECONO-
MIZERS - Includes a slide-in / plug-in damper assembly
with fully modulating spring-return motor actuator capa-
ble of introducing up to 100% outdoor air with nominal
1% leakage type dampers.
The enthalpy system contains one sensor that monitors
the outdoor air and determines when the air is cool
enough and dry enough to provide free cooling.
The rainhood is painted to match the basic unit and must
be field-assembled before installing.
MOTORIZED OUTDOOR AIR INTAKE DAMPER -
Includes a slide-in / plug-in damper assembly with a 2-
position, spring return motor actuator which opens to a
pre-set position whenever the supply air blower is oper-
ating and will drive fully closed when the blower unit
shuts down.
The rain hood is painted to match the basic unit and
must be field assembled before installing.
PHENOLIC COATED EVAPORATOR AND CON-
DENSER COILS - Special coating process that utilizes
Technicoat 10-1
TM
processes. Coating is applied by total
immersion of the complete coil for maximum protection.
ELECTRIC HEATERS - Wired for single point power
supply. These nickel chromium heater elements are pro-
vided with limit and automatic reset capability to prevent
operation at excessive temperatures.
FILTER OPTIONS - Standard units are shipped with 1”
throw-away filters installed. 2” pleated filters are offered
as a factory installed option.
CONVENIENCE OUTLET - This 110 volt outlet can be
“powered” by the unit with a stepdown transformer or the
unit may be ordered with a “non-powered” convenience
outlet that can be wired in the field.
DISCONNECT SWITCH - For gas heat units and cooling
units with electric heat, a HACR breaker sized to the unit
is provided. For cooling only units, a switch sized to the
largest electric heat available for the particular unit is
provided. Factory installed option only.
BAS - Building Automation System Controls
Simplicity
™ INTELLI-Comfort™ CONTROL - The
York® Simplicity™ INTELLI-Comfort™ control is factory
installed. It includes a supply air sensor, a return air sen-
sor, and an outside air sensor. There are provisions for a
field installed dirty filter indicator switch, an air-proving
FIGURE 1 - UNIT CUTAWAY

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the York SUNLINE 2000 DM 048 and is the answer not in the manual?

York SUNLINE 2000 DM 048 Specifications

General IconGeneral
BrandYork
ModelSUNLINE 2000 DM 048
CategoryAir Conditioner
LanguageEnglish

Summary

Single Package Unit Overview

Product Description and Features

Summarizes key aspects and benefits of the units.

Warranty Coverage Details

Outlines the different warranty periods for unit components.

Product Model Number Nomenclature

Decoding the Model Number

Breaks down the model number into its constituent parts and meanings.

Key Unit Features and Controls

Simplicity™ Control System Features

Details advanced control functions like low ambient and diagnostics.

Factory Installed Options

Economizer and Damper Options

Covers advanced air management systems for ventilation.

Wiring and Connection Diagrams

Typical Power Wiring Connections

Shows how to connect single and three-phase power supplies.

Guide Specifications - General

General Unit Construction and Standards

Covers manufacturing, ISO certification, and base rails.

Unit Control System Details

Control Board Features, Safety, and Diagnostics

Details lockout circuits, safety switches, and fault codes.

Heating, Operation, and Electrical Requirements

Related product manuals