TABLE 24: ELECTRICAL DATA - DM060 & 072 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET
NONE 0.0 0.0 55.0 80
2CE04510506 4.0 19.2 55.0 80
2CE04510706 5.6 26.9 55.7 80
2CE04511006 8.0 38.5 70.1 80
2CE04511506 11.9 57.2 93.5 100
2CE04512006 15.9 76.4 117.6 125
2CE04513006 22.2 106.7 155.4 175
NONE 0.0 0.0 55.0 80
2CE04510506 5.3 22.1 55.0 80
2CE04510706 7.5 31.3 61.1 80
2CE04511006 10.6 44.2 77.2 80
2CE04511506 15.9 66.3 104.8 110
2CE04512006 21.2 88.3 132.4 150
2CE04513006 29.6 123.3 176.2 200
NONE 0.0 0.0 36.5 50
2CE04510525
2
4.0 11.1 36.5 50
2CE04510725
2
5.6 15.5 38.4 50
2CE04511025 8.0 22.2 46.8 50
2CE04511525 11.9 33.0 60.3 70
2CE04512025 15.9 44.1 74.2 80
2CE04513025 22.2 61.6 96.0 100
NONE 0.0 0.0 36.5 50
2CE04510525
2
5.3 12.7 36.5 50
2CE04510725
2
7.5 18.0 41.6 50
2CE04511025 10.6 25.5 50.9 60
2CE04511525 15.9 38.2 66.8 70
2CE04512025 21.2 51.0 82.7 90
2CE04513025 29.6 71.2 108.0 110
NONE 0.0 0.0 18.4 25
2CE04510746
2
6.8 8.2 19.7 25
2CE04511046
2
10.1 12.1 24.7 25
2CE04511546
2
13.6 16.4 29.9 30
2CE04512046
2
19.5 23.5 38.8 40
2CE04513046
2
28.8 34.6 52.8 60
NONE 0.0 0.0 14.2 20
2CE04511058 10.6 10.2 19.7 20
2CE04511558 15.9 15.3 26.1 30
2CE04512058 21.2 20.4 32.5 35
2CE04513058 30.4 29.3 43.6 45
NONE 0.0 0.0 39.9 50
2CE04510525
2
4.0 11.1 39.9 50
2CE04510725
2
5.6 15.5 39.9 50
2CE04511025 8.0 22.2 46.5 50
2CE04511525 11.9 33.0 60.0 70
2CE04512025 15.9 44.1 73.9 80
2CE04513025 22.2 61.6 95.8 100
NONE 0.0 0.0 39.9 50
2CE04510525
2
5.3 12.7 39.9 50
2CE04510725
2
7.5 18.0 41.3 50
2CE04511025 10.6 25.5 50.6 60
2CE04511525 15.9 38.2 66.6 70
2CE04512025 21.2 51.0 82.5 90
2CE04513025 29.6 71.2 107.8 110
NONE 0.0 0.0 20.2 25
2CE04510746
2
6.8 8.2 20.2 25
2CE04511046
2
10.1 12.1 24.6 25
2CE04511546
2
13.6 16.4 29.8 30
2CE04512046
2
19.5 23.5 38.7 40
2CE04513046
2
28.8 34.6 52.7 60
NONE 0.0 0.0 15.7 20
2CE04511058 10.6 10.2 19.7 20
2CE04511558 15.9 15.3 26.1 30
2CE04512058 21.2 20.4 32.5 35
2CE04513058 30.4 29.3 43.6 45
28.9
460-3-60
5.2
0.8 2.6
165
125
10.0
230-1-60 28.9 165 1.3 7.6 10.0
1.3 7.6208-1-60
10.0
230-3-60 16.0 125 1.3 5.2 10.0
208-3-60 16.0 1.3
2 4.0
8.0 66.5
1.3 5.0 10.0
230-3-60 18.9 146 1.3 5.0 10.0
208-3-60
0.8 2.5 5.0
575-3-60 7.6 58.4 0.8 2 4.0
460-3-60
Minimum
Circuit
Ampacity
Amps
Max Fuse /
BRKR
1
Size
Amps
RLA
Each
LRA
Each
ID Blower
Motor
FLA
Conv
Outlet
Amps
Electric Heater
Model No.
Heater
kW
Compressors
5
Heater
Amps
OD Fan
Motor
FLA
Model
Tonnage
Voltage
5.0
575-3-60 6.4 50 0.8
6
18.9 146
9.5 73
1. HACR Type per NEC.
2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories
2FB04700825 and 2FB04700846 are available for field installation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York SUNLINE 2000 DM 048 and is the answer not in the manual?

York SUNLINE 2000 DM 048 Specifications

General IconGeneral
BrandYork
ModelSUNLINE 2000 DM 048
CategoryAir Conditioner
LanguageEnglish

Related product manuals