frame of a truck can works like a “local earth ground”, absorbing excess
charge. So it is strongly suggested to connect to truck frame all the
parts of the truck which can be touched by the operator, who is
most of the time the source of ESD.
4.5 Various suggestions
- Never combine SCR low frequency choppers with COMBI AC0/ ACE0
modules. The filter capacitors contained in the COMBI AC0/ ACE0 module
would change the SCR chopper operation and subject to excessive
workload. If it is necessary to use two or more control units, like the chopper
should be of the Zapimos family.
During battery recharge, the COMBI AC0/ ACE0 must be completely
disconnected from the battery. Beside changing the charging current seen by the
battery charger, the module can be damaged by higher than normal voltages
supplied via the charger.