EasyManuals Logo
Home>Zapi>Inverter>COMBI AC0

Zapi COMBI AC0 User Manual

Zapi COMBI AC0
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Page - 6/79 AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
2 SPECIFICATION
2.1 Technical specifications Combi AC0 / ACE0
Inverter for traction AC asynchronous 3-phase motors plus chopper for DC series
pump motors.
Regenerative braking functions.
Digital control based upon microcontroller
Voltage:..................................................................................................24, 36, 48V
Inverter maximum current (24V, 36V):........................................ 220A (RMS) for 2'
Inverter maximum current (36V, 48V):........................................ 180A (RMS) for 2'
Continuous output current (24V, 36V): ..............................105A (RMS) continuous
Continuous output current (36V, 48V): ................................90A (RMS) continuous
Inverter operating frequency:...........................................................................8kHz
Dc chopper Maximum current (24V,36V)(1): ......................................... 270A for 2'
Dc chopper Maximum current (36V, 48V)(1): .........................................220A for 2’
Chopper Operating frequency(1): ..................................................................16kHz
External temperature working range:..................................................-40°C ÷ 40°C
Maximum heatsink temperature (start of the thermal cutback)........................85°C
4 Note(1): The DC chopper specifications are related to Combi AC0
2.2 Technical specifications Combi AC0 Power / ACE0 Power
Inverter for traction AC asynchronous 3-phase motors plus chopper for DC series
pump motors.
Regenerative braking functions.
Digital control based upon microcontroller
Voltage:..................................................................................................24, 36, 48V
Inverter maximum current (24V, 36V):........................................ 320A (RMS) for 2'
Inverter maximum current (36V, 48V):........................................ 280A (RMS) for 2'
Continuous output current (24V, 36V): ..............................130A (RMS) continuous
Continuous output current (36V, 48V): ..............................110A (RMS) continuous
Inverter operating frequency:...........................................................................8kHz
Dc chopper Maximum current (24V,36V)(1): ......................................... 270A for 2'
Dc chopper Maximum current (36V, 48V)(1): .........................................220A for 2’
Chopper Operating frequency(1): ..................................................................16kHz
External temperature working range:..................................................-40°C ÷ 40°C
Maximum heatsink temperature (start of the thermal cutback)........................85°C
4 Note(1): The DC chopper specifications are related to Combi AC0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi COMBI AC0 and is the answer not in the manual?

Zapi COMBI AC0 Specifications

General IconGeneral
BrandZapi
ModelCOMBI AC0
CategoryInverter
LanguageEnglish

Related product manuals