Page - 50/79 AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
inching demand is active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the reverse demand is not active.
28) DI11 SWITCH
ON/OFF. This is the level of the CNA#18 digital input:
- ON GND = When CNA#18 is not closed to a battery (key) voltage (or
connected to GND) the digital input#11 is active.
- OFF +VB = When CNA#18 is closed to a battery (key) voltage the digital
input#11 is not active.
29) DI12 SWITCH
ON/OFF. This is the level of the digital input CNA#21:
- ON +VB = When it is closed to a battery (key) voltage the digital input#12
is active.
- OFF GND = When it is not closed to a battery (key) voltage (or it is
connected to GND) the digital input#12 is not active.
30) SET POINT EVP
This parameter shows the setpoint of EVP valve.
31) SET POINT EVP2
Show the percentage of voltage applied to EVP2 valve.
32) OUTPUT EV1
On/Off: determines if the valve EV1 or EV5 are open or closed.
33) OUTPUT EV2
On/off: determines if the valve EV2 is open or closed.
34) OUTPUT EV3
On/off: determines if the valve EV3 is open or closed.
35) OUTPUT EV4
On/off: determines if the valve EV4 is open or closed.