18 CHAPTER 1: INTRODUCING THE SUPERSTACK 3 SWITCH 4400
Off No power is being delivered.
Status Yellow flashing PoE POST error on port. Flash rate is 4 Hz
Module LEDs
Packet Refer to the user documentation accompanying the module, if installed.
Status Refer to the user documentation accompanying the module, if installed.
Off There is no module installed in the expansion module slot.
Yellow flashing
(fast)
The module has failed and has been automatically disabled.
The Switch passes its Power On Self Test and continues to
operate normally even if one or more modules are disabled.
Unit LEDs
1–8 Green When the Switch forms a stack with other Switch 4400
units, the LED indicates the position of the unit in the stack
and that a link is present.
When the Switch is stand-alone and not part of a stack, LED
1 is on.
Green
sequential
When a software upgrade is in progress, the Unit LEDs of the
unit that is being upgraded flash on and off in the following
sequence —
1,2,4,6,8,7,5,3 (24-port)
1,2,3,4,8,7,6,5 (48-port)
Green
flashing
The Switch physically forms a stack with other Switch 4400
units, but cannot be managed as part of that stack until all
units have been upgraded to software version 2.0 or later.
Off A fault has occurred.
Power/Self Test LED
Green The Switch is powered-up and operating normally.
Green flashing The Switch is either downloading software or is initializing
(which includes running a Power On Self Test).
Yellow The Switch has failed its Power On Self Test
or
A port has failed and has been automatically disabled. You
can verify this by checking that the Port LED Status LED is
quickly flashing Yellow. If a port fails the Switch passes its
Power On Self Test and continues to operate normally.
Off The Switch is not receiving power or there is a fault with the
Power Supply Unit.
LED Color Indicates
DUA1720-3AAA05.book Page 18 Friday, March 7, 2003 11:53 AM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3Com SuperStack 3 Switch 4400 Series and is the answer not in the manual?

3Com SuperStack 3 Switch 4400 Series Specifications

General IconGeneral
Brand3Com
ModelSuperStack 3 Switch 4400 Series
CategorySwitch
LanguageEnglish

Related product manuals