Technical data 107
Three-phase supply voltage 380 V, 400 V or 415 V
-0003-3 5.1 6.5 1.5 4.7 1.5 3.4 1.1 R2 35 100
-0004-3 6.5 8.2 2.2 5.9 2.2 4.3 1.5 R2 35 120
-0005-3 8.5 10.8 3 7.7 3 5.7 2.2 R2 35 140
-0006-3 10.9 13.8 4 10.2 4 7.5 3 R2 35 160
-0009-3 13.9 17.6 5.5 12.7 5.5 9.3 4 R2 35 200
-0011-3 19 24 7.5 18 7.5 14 5.5 R3 69 250
-0016-3 25 32 11 24 11 19 7.5 R3 69 340
-0020-3 34 46 15 31 15 23 11 R3 69 440
-0025-3 44 62 22 41 18.5 32 15 R4 103 530
-0030-3 55 72 30 50 22 37 18.5 R4 103 610
-0040-3 72 86 37 69 30 49 22 R5 250 810
-0050-3 86 112 45 80 37 60 30 R5 250 990
-0060-3 103 138 55 94 45 69 37 R5 250 1190
-0075-3 145 170 75 141 75 100 45 R5 405 1440
-0070-3 * 141 164 75 132 55 97 45 R6 405 1440
-0100-3 166 202 90 155 75 115 55 R6 405 1940
-0120-3 202 282 110 184 90 141 75 R6 405 2310
-0135-3 225 326 110 220 110 163 90 R6 405 2810
-0165-3 260 326 132 254 132 215 110 R6 405 3260
-0205-3 290 351 160 285 160 234 132 R6 405 4200
Three-phase supply voltage 380 V, 400 V, 415 V, 440 V, 460 V, 480 V or 500 V
-0004-5 4.9 6.5 2.2 4.5 2.2 3.4 1.5 R2 35 120
-0005-5 6.2 8.2 3 5.6 3 4.2 2.2 R2 35 140
-0006-5 8.1 10.8 4 7.7 4 5.6 3 R2 35 160
-0009-5 10.5 13.8 5.5 10 5.5 7.5 4 R2 35 200
-0011-5 13.2 17.6 7.5 12 7.5 9.2 5.5 R2 35 250
-0016-5 19 24 11 18 11 13 7.5 R3 69 340
-0020-5 25 32 15 23 15 18 11 R3 69 440
-0025-5 34 46 18.5 31 18.5 23 15 R3 69 530
-0030-5 42 62 22 39 22 32 18.5 R4 103 610
-0040-5 48723044303622 R4103810
-0050-5 65 86 37 61 37 50 30 R5 250 990
-0060-5 79 112 45 75 45 60 37 R5 250 1190
-0070-5 96 138 55 88 55 69 45 R5 250 1440
-0105-5 145 170 90 141 90 100 55 R5 405 2150
-0100-5 * 124 164 75 115 75 88 55 R6 405 1940
-0120-5 157 202 90 145 90 113 75 R6 405 2310
-0140-5 180 282 110 163 110 141 90 R6 405 2810
-0165-5 225 326 132 220 132 163 110 R6 405 3260
-0205-5 260 326 160 254 160 215 132 R6 405 3800
-0255-5 290 351 200 285 200 234 160
R6 405 4500
* Type no longer available
ACS800-01
size
Nominal
ratings
No-
overload
use
Light-overload
use
Heavy-duty use Frame
size
Air flow Heat dis-
sipation
(1
I
cont.max
A
I
max
A
P
cont.max
kW
I
2N
A
P
N
kW
I
2hd
A
P
hd
kW
m
3
/h
W