40 Advance Optima Ex Analyzer Modules Operators Manual 42/24-12-2 EN
Electrical Equipment in Explosion Hazard Zones:
Legal Principles
ElexV Set-up, installation and operation of the explosion-protection versions of the
Advance Optima Analyzer System in the Federal Republic of Germany is covered
by the 13 December 1996 "Regulations on Electrical Equipment in Explosion
Hazard Zones" (ElexV).
Classification of
Explosion Hazard
Zones
Areas in which combustible gases, vapors or fogs pose a risk of explosion are
classified as zones. Zones are distinguished by their respective probability of
containing explosive atmospheres:
Zone 0 Covers areas in which explosive atmospheres occur continuously or on a
long-term basis.
Zone 1 Covers areas in which explosive atmospheres may occasionally be
present.
Zone 2 Covers areas in which explosive atmospheres are infrequently present or
occur only for short periods of time.
Operation of Electrical
Equipment in Zone 1
Only electrical equipment with an EC type certification may be used in Zone 1
explosion hazard areas.
Operation of Electrical
Equipment in Zone 2
Electrical equipment used in Zone 2 explosion hazard areas must have
An EC type certification or
A manufacturers certificate of suitability for use in Zone 2
Manufacturers
Certification
By affixing a label (see "Operating Data", Page 30) the manufacturer confirms that
unit testing was successfully completed and that the product is in accordance with
the documentation submitted to the testing office.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB Advance Optima Caldos 15-Ex and is the answer not in the manual?

ABB Advance Optima Caldos 15-Ex Specifications

General IconGeneral
BrandABB
ModelAdvance Optima Caldos 15-Ex
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals