Document: v0.6 / Document No.: 6AGA000008-0102-EN | Date: 22-05-2019 Page 12 of 23
2.4 Charger configurations
The charger is built up with a modular architecture. Supported charging standards are:
100kW charge cabinet configuration with 1-3 Depot charge boxes,
supporting CCS-2 with CE certification
150kW charge cabinet configuration with 1-3 Depot charge boxes,
supporting CCS-2 with CE certification
100kW charge cabinet configuration with 1-3 Depot charge boxes,
supporting CCS-1 with UL certification
150kW charge cabinet configuration with 1-3 Depot charge boxes,
supporting CCS-1 with UL certification
For each product configuration (100 or 150kW, CE or UL) it is possible to connect 1 up to
3 Depot Charge boxes.
2.5 Authorization to charge
The standard setting is without authorization. This means that every vehicle supporting
CCS is able and allowed to start a charge session. Operating a charger with authoriza-
tion requires a subscription to a back office. Authorization can only be done based on
the Vehicle ID and requires a subscription to a back office. This product does not sup-
port a RFID reader.