EasyManuals Logo

ABB PSTX370 Service Manual

ABB PSTX370
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
1SFC13105M0201 | Service Manual | Description 15
2.1.8 Identification of Softstarter type
NOTE
The service kits and spare parts varies depending on
the type and serial number of the Softstarter. It is essential
that the corresponding service kits and spare parts is
used. Always refer to the spare parts catalogue when
ordering service kits and spare parts. The spare parts
catalogue, 1SFC001013C0201, is to be found on
www.abb.com/lowvoltage.
Identification
The Softstarter is identified by the front label
A
.
Terminal marking of main circuit
B
.
A
Front label
Order code
2
.
Technical data according to IEC 60947-4-2
3
.
Technical data according to UL 508
4
.
The label shows the Softstarter and the serial number.
C
Serial number information
The ABB Serial number within business unit Control
Products has the following structure:
Table 5
Prefix Register Id Individual identity number part
1S 160 PPPP YY WW NNNN
Prefix = Defined in ABB Corporate Standard 9AAK100359
Register Id = Defined in BAATLV Instruction 1SFD2000-8
Individual identity number part
PPPP = Identification for product type / part of product
YY = Manufacturing year. Two digits.
(e.g. 02 for year 2002)
WW = Manufacturing Week. Two digits.
NNNN = Running number with week. Minimum four digits,
starting with 1000 each week.
Com1 Com2
2
3
4
A
B
B
1SFA 894 007 R1002
Ie: 37-72A
UL 508
Uc: 100-250V AC/DC
FLA: 37-68A
Ue 208 220-240 440-480 V
In line 20 20 50 Hp
Overload Capacity 115% of Continuous
1234567891011121314151617181920
100-250V
L
N
Stop
Start
In1VcVn Vp Vp
K4
In0
50/60 Hz
K5 K6
PTCKeypad Fieldbus
1L1
2T14T2 6T3
B1 B2 B3
3L25L3
LISTED
IND. CONT. EQ
7F39
IEC 947-4-2
Us: 100-250V AC/DC
Ue: 220-230 380-400 500 V
72: AC-53a: 8-1.6: 80-6
In line 18,5 37 45 kW
LI
ST
ED 7F39
I
ND. C
O
NT.
E
Q
.
Ie: 3
7-72A
Us: 1
0
0-250
V A
C
/D
C
UL
Uc:
1
0
0-
2
5
0
V A
C
/D
C
F
L
A: 37
-6
8
A
Ue
: 2
20-
2
3
0 380
-40
0 5
00
V
In
line
18,5
3
7
45
k
W
Ue
208
220
-2
40
4
40-4
8
0 V
In line
20
2
0
50
Hp
CAUTIO
N
F
u
se 2
5
0
A
T
YPO
WER ZIL
O
X
Max
sh
ort
ci
rcu
i
t curr
ent 6
5kA
at
Wi
re
1
-
8
A
l C
u
75C on
ly,
3
5
lb
-in
O
verl
oad Capa
ci
ty
1
1
5% of
C
on
ti
n
uo
u
s
PTC
Keypad
Fieldbus
1
S
1
601
00
1
0302
0123
123456
78
9101
1
1213
Bypass connection
(PST30...300 only)
Terminal marking
of control circuits
Control voltage U
e
For identification of Softstarter, see chapter
2.1.9 Identification of Softstarter type
Line side
connection
Power on ProtectionFault
1 2
3
4
Figure 1:
1 Status indication LEDs
2 LCD display
3 Selection keys for selecting, changing and storing parameters
4 Navigation keys for navigating in the menus
* Arrows shown in the display indicate that the value/menu is
possible to change or scroll
5
L
100-250V
50/60 Hz K4 K5 K6
StartStopIn1 In2DGND+24VGND
N
In0
Ready
Run Fault
Protection
PSTX
1S160
1
0010
3
02
01
23
12345
67
8
9
101
11
21
3
C
2

Other manuals for ABB PSTX370

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PSTX370 and is the answer not in the manual?

ABB PSTX370 Specifications

General IconGeneral
BrandABB
ModelPSTX370
CategoryController
LanguageEnglish

Related product manuals