Installation
42/68-167-EN RHDE250 ... 4000 (Contrac) 13
Pos: 11.1 /Überschri ften/1/M - R/Montage @ 0\mod_1 140519732218_3101. doc @ 3159
4 Installation
Pos: 11.2 /Überschri ften/1.1/1-spa ltig/A - F/Antriebskontr olle @ 10\mod_11816325270 31_3101.doc @ 103415
4.1 Actuator check
Pos: 11.3 /Montage/A ktorik/Elektr. S chwenkantriebe/Allge mein/Antriebskontr olle @ 10\mod_1181568760 671_3101.doc @ 103037
Before you start to install the actuator make sure that the delivery status corresponds to the
ordered status and to the intended use.
Check the oil level when installing the device in positions other than IMB 3.
Did you fasten the separately delivered venting plug (spare part no. 9287338) in the
uppermost bore (depending on the mounting orientation)?
Make sure that the motor and the connection chambers are free of dirt, moisture and
corrosion.
Pos: 11.4 /Überschri ften/1.1/1-spa ltig/A - F/Einbaulage @ 3\mod _1158651041937_3101.d oc @ 41702
4.2 Mounting position
Pos: 11.5 /Montage/A ktorik/Elektr. Schwenkantriebe/RHDE250 ...4000/Einbaula ge Zeichnung @ 10\mod_1181 815089156_3101.doc @ 106121
The spur gears of the actuator RHDE250 ... 4000 (Contrac) are oil lubricated. They contain the
max. oil quantity when leaving the manufacturer. Once the actuator is installed replace the
uppermost check plug by the separately supplied venting plug.
IMB 3
IMB 6
IMB 7
IMV 6
1
2
M00304
Fig. 3
1 Inspection plug 2 Venting plug
Pos: 11.6 /Montage/A ktorik/Elektr. Schwenkantriebe/RHDE250 ...4000/Einbaula ge RHDE250...4000 @ 10\mod_1181633 075968_3101.doc @ 103484
All mounting orientations shown in fig. Fig. 3 are permissible. To facilitate mounting and
maintenance, however, it is recommended to use orientation IMB 3. For each mounting
position, check the oil level prior to commissioning.
In order to ensure sufficient ventilation and space for the motor de-/installation allow for the
following min. space to the motor hood:
Actuator Space
RHDE250 60 mm (2.36 inch)
RHDE500/800 60 mm (2.36 inch)
RHDE1250/2500 80 mm (3.15 inch)
RHDE4000 80 mm (3.15 inch)
Pos: 11.7 /====== = Seitenumbruch ======= = @ 0\mod_1126532365768_3101.doc @ 3830

Table of Contents

Other manuals for ABB RHD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RHD Series and is the answer not in the manual?

ABB RHD Series Specifications

General IconGeneral
BrandABB
ModelRHD Series
CategoryController
LanguageEnglish

Related product manuals