TERR A 54 / 54 H V CHAR G ER
2018- 10- 03 35/40
8 Technical Data
8.1 Electrical data
Input
Supply voltage
3 phase, 400 V AC: PE, N, L1, L2, L3
Input voltage range
400 V AC +/- 10% (50 Hz or 60 Hz)
Maximum rated input current & power
125 A, 86 kVA
Power factor
> 96%
Efficiency
95% at nominal output power
DC output (C)
Maximum output power
50 kW
Output voltage range
200-500 V DC (CCS 2)
Maximum output current
125 A DC +/- 5% (CCS 2)
DC output (C HV)
Maximum output power
50 kW
Output voltage range
200-950 V DC (CCS 2)
Maximum output current
125 A DC +/- 5% (CCS 2)
DC output (J)
Maximum output power
50 kW
Output voltage range
200-500 V DC (CHAdeMO)
Maximum output current
120 A DC (CHAdeMO)
DC output (J HV)
Maximum output power
50 kW
Output voltage range
200-950 V DC (CHAdeMO)
Maximum output current
120 A DC (CHAdeMO)
Option: AC output socket (T)
Maximum output power
22 kW
Max AC output current
3 x 32 A
Output Voltage Range
400 V +/- 10%
Option: AC output Cable (G)
Maximum output power
22 kW / 43 kW

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB Terra 54 Series and is the answer not in the manual?

ABB Terra 54 Series Specifications

General IconGeneral
Output Power50 kW
Display7-inch touchscreen
Network ConnectivityEthernet, Wi-Fi, 4G
Enclosure RatingIP54
Charging StandardsCHAdeMO, CCS
Communication ProtocolsOCPP 1.6
Input Voltage400 V AC
Current125 A