Operation Manual / TPL85-B14/-B15/-B16
Short
-term turbocharger shut-down
9
Possibilities for emergency repair
9.1
Page 115
© Copyright 2016 ABB. All rights reserved.
May 2016 HZTL2491_EN Revision B
Short-term turbocharger shut-down
Possibilities for emergency repair
9.1
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can cause severe personal
injury or fatal accidents can result.
Cordon off danger area.
Sound an alarm and depending on the situation, stop the engine.
Seal oil leaks.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-
compliance with the directives for locking/blanking off the turbocharger
on the engine.
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as possi-
ble after damage to the turbocharger (emergency repair), the following
possibilities are available:
Locking turbocharger rotor
Shutting off inlets and outlets
Turbocharger bypass
NOTICE
Emergency repairs that can be carried out quickest have been de-
scribed first.
9
9.1

Table of Contents

Other manuals for ABB TPL85-B14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB TPL85-B14 and is the answer not in the manual?

ABB TPL85-B14 Specifications

General IconGeneral
BrandABB
ModelTPL85-B14
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals