New HC Series User Manual - 17 -
4. Product Cabling
Preparation before cabling
Before applying power and signal source to the screen, please check power and data cables
connections carefully and make sure they are wired correctly. Use a multimeter to test the L, N
and PE lines in AC power input port and make sure the three lines are not short-circuited.
Power cable connection instructions: Please calculate and select the appropriate model of
distribution cabinet or socket according to the maximum power consumption. Please consult your
electrician or distribution cabinet manufacturer for specific selection scheme. The input voltage
of the cabinet is 100-240V/AC. The 3×1.5 mm
2
power cable is used from the distribution box to
the cabinet. Please confirm the input voltage, the number of cabinets loaded on each power cable
will be different upon different voltages and product models. (Please feel free to contact our
after-sales service department if you cannot confirm).
4.1 Power Supply Wiring
Taking a [4x4] HC1.2 Ⅱ cabinet for example, data and power wiring schematics are shown
below:
The total power of 16 HC1.2 Ⅱ cabinets is 16 x 0.6 x 0.3375 x 520W=1.7kW. First, connect the
cabinets in series with connecting power lines, and the 3×1.5 mm
2
power cable is used for
connecting from the cabinet of bottom layer to the distribution box or socket.
NOTE: WHEN THE INPUT VOLTAGE IS 220V, EACH 3×1.5 MM
2
POWER CABLE CAN CARRY UP TO 16 CABINETS. WHEN THE INPUT
VOLTAGE IS 110V, EACH POWER CABLE CAN CARRY UP TO 8 CABINETS.