Specification 1769-OF8C
System Power Supply Distance
Rating
The module may not be more than 8 modules away from the system power
supply.
Optional 24V dc Class 2 Power
Supply Voltage Range
(1)
20.4 V to 26.4 V dc
Recommended Cable Belden™ 8761 (shielded)
Vendor I.D. Code 1
Product Type Code 10
Product Code 40
Input Words 11
Output Words 9
Configuration Words 64
(1)
Failure to use a Class 2 power supply without regulation within these limits could result in improper module operation.