15 Rockwell Automation Publication 1783-IN022A-EN-P - July 2023
Stratix 5200 Ethernet Managed Switches Installation Instructions
Specifications
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
You can view or download publications at http://www.rockwellautomation.com/global/literature-library/overview.page
. To order paper copies of technical documentation, contact
your local Allen-Bradley distributor or Rockwell Automation sales representative.
Attribute 1783-CMS6B 1783-CMS6P 1783-CMS10B 1783-CMS10P 1783-CMS10DP 1783-CMS10DN 1783-CMS20DB 1783-CMS20DP 1783-CMS20DN
Temperature, operating -40°C < Ta < +60 °C (-40° F < Ta < +140° F)
Enclosure type rating None (open-style)
Power consumption 14 W 17.7 W 28 W 36.7 W
Inrush current, max
10 A for 7 ms with 12V input
6 A for 6 ms with 24V input
6 A for 6 ms
Power input
1.6 A with 12V input
0.8 A with 24V input
0.4 A with 48V input
2.0 A with 12V input
1.0 A with 24V input
0.5 A with 48V input
3.2 A with 12V input
1.6 A with 24V input
0.8 A with 48V input
4.2 A with 12V input
2.6 A with 24V input
1.3 A with 48V input
AMP Rating 12…48V DC, 1.6 A Max 12…48V DC, 2.0 A Max 12…48V DC, 3.2 A Max 12…48V DC, 4.2 A Max
I/O’s RJ45 Console, USB
Alarm relay
(1)
(1) The alarm rating for all models is 60V, 0.5A or 30V, 1A (resistive load only).
30V DC, 1.0 A; 60V DC, 0.5 A
Total ports 6 10 20
Voltage nominal 12V…48V
Wire size, DC power
connections
0.5…0.8 mm
2
(20…18 AWG) twisted-pair supply wires suitable for minimum 104 °F (40 °C) above ambient temperature
Wire size, ground
connection
4.0 mm
2
(12 AWG) min, stranded copper wire
Wire size, alarm
connections
0.5…0.8 mm
2
(20...18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire (such as Belden part number 9318),
6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.) strip length
Screw torque,
power terminals
0.51 N•m (4.5 in•lb)
Screw torque,
ground terminals
0.4 N•m (3.5 in•lb)
Screw torque, alarm
terminals
0.23 N•m (2.0 in•lb), max
Pilot duty rating Alarm not rated
North American temp
code
T4
ATEX temp code T4
Resource Description
Stratix Ethernet Device Specifications Technical Data, publication 1783-TD001
Provides specification information for Ethernet switches and other devices.
Stratix Managed Switches User Manual, publication 1783-UM007
Provides information about configuring, monitoring, and troubleshooting the switches.
Stratix Ethernet Managed Switches User Manual, publication 1783-UM012
Describes how to configure and troubleshoot Stratix 5200 and 5800 switches.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, rok.auto/certifications
Provides declarations of conformity, certificates, and other certification details.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Stratix 5200 1783-CMS20DN and is the answer not in the manual?

Allen-Bradley Stratix 5200 1783-CMS20DN Specifications

General IconGeneral
BrandAllen-Bradley
ModelStratix 5200 1783-CMS20DN
CategorySwitch
LanguageEnglish

Related product manuals