Rockwell Automation Publication 1783-IN022A-EN-P - July 2023 4
Stratix 5200 Ethernet Managed Switches Installation Instructions
ATTENTION: This equipment is certified for use only within the surrounding air temperature range of -40…+60 °C (-40…+140 °F). The equipment must not
be used outside of this range.
ATTENTION: Power to this equipment and all connected I/O must be supplied from a source compliant with the following:
Class 2 approved to UL1310
SELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1)
PELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1)
ATTENTION: Use SFP modules from only Rockwell Automation. For details about supported modules, see the Stratix® Ethernet Device Specifications
Technical Data, publication 1783-TD002.
ATTENTION: For proper grounding, you must always connect the power supply functional-ground screw when connecting the power supply. You must
provide an acceptable grounding path for each device in your application. For more information on proper grounding guidelines, refer to publication 1770-4.1,
Industrial Automation Wiring and Grounding Guidelines.
ATTENTION: The alarm port cables are not to exceed 10.0 m (32.81 ft).
WARNING:
This equipment is not resistant to sunlight or other sources of UV radiation.
This equipment shall be mounted in an ATEX Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 (in accordance with
UL 60079-0) and used in an environment of not more than Pollution Degree 2 (as defined in EN 60664-1) when applied in Zone 2 environments. The enclosure
must be accessible only by the use of a tool.
This equipment shall be used within its specified ratings defined by Rockwell Automation.
Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the peak rated voltage when
applied in Zone 2 environments.
The instructions in the user manual shall be observed.
Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this
product.
Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous.
The USB port is intended for temporary local programming purposes only and not intended for permanent connection. Do not use the USB port in hazardous
locations.
UK and European Hazardous Location Approval
The following applies to products marked II 3 G: Such modules:
Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design and construction of such equipment
given in Annex II to EU Directive 2014/34/EU and Schedule 1 of the UKEX Regulation 2016 No. 1107. See the UKEX and EU Declaration of Conformity at rok.auto/certifications for
details.
The type of protection is <Ex ec nC IIC T4 Gc> Equipment protection by increased safety “e”.
Equipment protection by increased safety “e”, reference certificate numbers UL 23 ATEX 3010X and UL23UKEX2858X.
Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for
short periods. Such locations correspond to Zone 2 classification according to UKEX Regulation 2016 No. 1107 and ATEX directive 2014/34/EU.
WARNING: If you connect or disconnect the communications cable with power applied to this module or any device on the network, an electric arc can occur.
This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
WARNING: If you connect or disconnect wiring while the field-side power is on, an electric arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before proceeding.
WARNING: When you insert or remove the CompactFlash/SD memory card while power is on, an electric arc can occur. This could cause an explosion in
hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Stratix 5200 1783-CMS20DN and is the answer not in the manual?

Allen-Bradley Stratix 5200 1783-CMS20DN Specifications

General IconGeneral
BrandAllen-Bradley
ModelStratix 5200 1783-CMS20DN
CategorySwitch
LanguageEnglish

Related product manuals