Error Codes
DELUXE CONTROL
Code Description Cause Remedy
door Door open Door is open
Close the door, check door
switch operation.
ProG Programmer error Fatal Error
Call Alto-Shaam technical
support
P111 Probe 1 open circuit, upper compartment
Open circuit detected on
sensor wires
1. Sensor connection
2. Sensor
3. Control Board
P110 Probe 1 short circuit, upper compartment
Short circuit detected on
sensor wires
P211 Probe 2 open circuit, upper compartment
P210 Probe 2 short circuit, upper compartment
P311 Probe 3 open circuit, upper compartment
P310 Probe 3 short circuit, upper compartment
P411 Probe 4 open circuit, upper compartment
P410 Probe 4 short circuit, upper compartment
P511 Probe 5 open circuit, upper compartment
P510 Probe 5 short circuit, upper compartment
P611 Probe 6 open circuit, upper compartment
P610 Probe 6 short circuit, upper compartment
P711 Probe 1 open circuit, lower compartment
P710 Probe 1 short circuit, lower compartment
P811 Probe 2 open circuit, lower compartment
P810 Probe 2 short circuit, lower compartment
P911 Probe 3 open circuit, lower compartment
P910 Probe 3 short circuit, lower compartment
PA11 Probe 4 open circuit, lower compartment
PA10 Probe 4 short circuit, lower compartment
Pb11 Probe 5 open circuit, lower compartment
Pb10 Probe 5 short circuit, lower compartment
PC11 Probe 6 open circuit, lower compartment
Open circuit detected on
sensor wires
PC10 Probe 6 short circuit, lower compartment
Short circuit detected on
sensor wires
1. Sensor connection
2. Sensor
3. Control Board
E-10 Cavity probe shorted
Short circuit detected on
sensor wires. Halts any active
program
1. Sensor connection
2. Sensor
3. Control Board
E-11 Cavity probe open
Open circuit detected on
sensor wires. Halts any active
program
1. Sensor connection
2. Sensor
3. Control Board

Table of Contents

Other manuals for Alto-Shaam 1750-TH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam 1750-TH and is the answer not in the manual?

Alto-Shaam 1750-TH Specifications

General IconGeneral
BrandAlto-Shaam
Model1750-TH
CategoryOven
LanguageEnglish

Related product manuals