34
4. Care and maintenance
Care for and maintain the Secuquick softline as follows:
Take apart and clean after each use.
Before using it again, check that it is working properly: Valves and seals, condition of the cover
closure.
Replace the sealing ring and other seals if they are damaged, brittle, shrunken or cracked.
These parts should be replaced at least every two years or after 400 cooking cycles.
Use only original spare parts for the relevant 4300 model.
Wear parts (sealing ring and gaskets) are available as spare parts from AMC. These can be replaced by the
user or by an AMC service center.
All other interventions may be carried out only by an AMC service center.
Designation in user manual AMC item no.
Sealing ring 20 cm / 24 cm 10011155 / 10011156
Sealing washer for the operating pressure valve 10011151
Steam-venting valve 10011187
O-ring for safety valve 2 10011134
Sealing cap for safety valve 3 10011149
O-ring under the Visiotherm S 10011185
4.1. Disassembling the Secuquick softline
Unscrew bell nut (6). Detach the bottom cover (7) from the top cover (8).
Remove the sealing ring (9) (tip: use a small spoon handle to help).
8
Table: Original sealing rings and seals:
EN