Axcess Programming
9
Axcent
3
and Axcent
3
Pro Integrated Axcess Controllers
Axcess Programming
Device and Channel Numbers
The following table lists the port type, device numbers, channels, with a brief description.
Send_Commands for RS-232/422/485 Ports
The table below lists the Send_Commands for the internal RS-232/422/485 ports.
Device and Channel Number Parameters
Port Type
Device
Numbers
Channels Description
RS-232/422/485 1 - 6 1 - 255 6 Rs-232/422/485 control ports with XON/XOFF(transmit on/
transmit off), and CTS/RTS (clear to send/ready to send), 300,
200 baud.
Relay 7 1 - 8 8-channel relay ports
IR/Serial/Data 8 - 13 1 - 254 6 IR/Serial/Data control ports that support high-frequency carri-
ers up to 1.14 MHz, and one-way data, 300 - 38,400 baud (0 - 5
VDC)
Input/Output 14 1 - 6 6-channel I/O port for contact closure, 0 - 5 VDC voltage sensing,
or interactive power sensing for IR ports
Axcess Control
Cards
15 - 18 Card
dependent
Card slots 1 - 4 (Axcent
3
Pro only)
Send_Commands for RS-232/422/485 Mode
B9MOFF
Sets the port’s com-
munication parame-
ters.
Sets the parameters for stop and data bits according to the software settings on the RS-
232 port (default).
Syntax:
’B9MOFF’
Example:
SEND_COMMAND RS232_1,’B9MOFF’
Sets the RS-232 port settings to match the port’s configuration settings.
B9MON
Overrides the com-
munication settings
on the RS-232 port.
Overrides settings to 9 data bits and 1 stop bit, and use the port’s active baud rate set-
tings.
Example:
SEND_COMMAND RS232_1,’B9MON’
Resets the RS-232 port’s communication parameters to 9 data bits, 1 stop bit, and
locks-in the baud rate set with the OpenAxcess software program.
CHARD
Sets the delay time
between transmitted
characters.
Syntax:
’CHARD-<0-255>’
Variables:
<0 - 255> = time in 100 microsecond increments
Example:
SEND_COMMAND RS232_1,’CHARD-100’
Sets 10 millisecond delay between all transmitted characters.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM and is the answer not in the manual?

AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM Specifications

General IconGeneral
BrandAMX
ModelAXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM
CategoryController
LanguageEnglish

Related product manuals