Axcess Programming
Device and Channel Numbers
The following table lists the port type, device numbers, channels, with a brief description.
Send_Commands for RS-232/422/485 Ports
The table below lists the Send_Commands for the internal RS-232/422/485 ports.
Device and Channel Number Parameters
Port Type
Device
Numbers
Channels Description
RS-232/422/485 1 - 6 1 - 255 6 Rs-232/422/485 control ports with XON/XOFF(transmit on/
transmit off), and CTS/RTS (clear to send/ready to send), 300,
200 baud.
Relay 7 1 - 8 8-channel relay ports
IR/Serial/Data 8 - 13 1 - 254 6 IR/Serial/Data control ports that support high-frequency carri-
ers up to 1.14 MHz, and one-way data, 300 - 38,400 baud (0 - 5
VDC)
Input/Output 14 1 - 6 6-channel I/O port for contact closure, 0 - 5 VDC voltage sensing,
or interactive power sensing for IR ports
Axcess Control
Cards
15 - 18 Card
dependent
Card slots 1 - 4 (Axcent
3
Pro only)
Send_Commands for RS-232/422/485 Mode
B9MOFF
Sets the port’s com-
munication parame-
ters.
Sets the parameters for stop and data bits according to the software settings on the RS-
232 port (default).
Syntax:
’B9MOFF’
Example:
SEND_COMMAND RS232_1,’B9MOFF’
Sets the RS-232 port settings to match the port’s configuration settings.
B9MON
Overrides the com-
munication settings
on the RS-232 port.
Overrides settings to 9 data bits and 1 stop bit, and use the port’s active baud rate set-
tings.
Example:
SEND_COMMAND RS232_1,’B9MON’
Resets the RS-232 port’s communication parameters to 9 data bits, 1 stop bit, and
locks-in the baud rate set with the OpenAxcess software program.
CHARD
Sets the delay time
between transmitted
characters.
Syntax:
’CHARD-<0-255>’
Variables:
<0 - 255> = time in 100 microsecond increments
Example:
SEND_COMMAND RS232_1,’CHARD-100’
Sets 10 millisecond delay between all transmitted characters.