EasyManuals Logo

Atlas Copco CLAWVAC CP65 User Manual

Atlas Copco CLAWVAC CP65
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
300676782_002_C0
6996 0229 87 Issue A 05/2017 © Leybold 42
Technical data
8.1 Reference conditions and limitations
Table 4 Reference conditions
Unit
Relative humidity
%
0
Air inlet temperature
°C
20
°F
68
Exhaust back pressure
mbar(g)
0
psi
0
Ambient barometric pressure
mbar(a)
1013
psi
14.7
Table 5 Limitations
Unit
Minimum ambient temperature
°C
0
°F
32
Maximum ambient temperature
°C
40
°F
104
Minimum allowable inlet temperature
°C
0
°F
32
Maximum allowable inlet temperature
°C
40
°F
104
Maximum (absolute) inlet pressure
mbar(a)
1050
psi
15.22
Maximum outlet pressure mbar(a) (vacuum pump)
mbar(a)
1013
psi
14.7
Maximum outlet pressure mbar(g) (over-pressure pump)
bar(g)
2.5
psi
36.3
8.2 Pump data
Note: The readings below are valid when operating at reference conditions. See section Reference
conditions.
Common pump data
Table 6 Common pump data
Unit
Number of compressions:
1
Maximum exhaust back pressure:
mbar(a)
1013
Torr
759.81
Temperature of the air leaving the discharge (Approx.)
°C
250
°F
482

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco CLAWVAC CP65 and is the answer not in the manual?

Atlas Copco CLAWVAC CP65 Specifications

General IconGeneral
BrandAtlas Copco
ModelCLAWVAC CP65
CategoryWater Pump
LanguageEnglish

Related product manuals