When a service plan interval is reached, a message will appear on the screen; see section Status
data menu. After carrying out the service actions related to the indicated levels, the timers must
be reset.
Example
Service plans Intervals
Service plan A Every 4000 running hours
Service plan B Every 4000 running hours
Service plan C Every 8000 running hours
Service plan D Every 24000 running hours
Resulting service actions according to At
Service plan A and B 4000 running hours
Service plan A, B and C 8000 running hours
Service plan A and B 12000 running hours
Service plan A, B and C 16000 running hours
Service plan A, B, C and D 24000 running hours
... ...
Procedure
Starting from the Main screen (see Main screen menu):
Press the key ‘Menu’ (F1).
Press the arrow down key (1) until ‘Service’ is followed by a horizontal arrow.
Activate the menu by pressing tabulator key (2).
A screen similar to the one below appears:
‘Service Timer’
‘Running Hours’
‘hrs’ 7971
‘Menu’
F1 F2 F3
The screen shows that the total compressor running time is 7971 hours.
Press the tabulator key (2); the following screen appears:
‘Next Timer’
‘Level’ A B C
‘hrs’ 8000
‘Back’ ‘Rset’
F1 F2 F3
The screen shows that the next service plans to be carried out are plans A, B and C and that
these plans are to be carried out every 8000 running hours.
Instruction book
40 API161475

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 11 VSD and is the answer not in the manual?

Atlas Copco GA 11 VSD Specifications

General IconGeneral
BrandAtlas Copco
ModelGA 11 VSD
CategoryAir Compressor
LanguageEnglish

Related product manuals