Digital outputs
Parameter Value
Number of outputs 9 (Elektronikon® Graphic controller - p.n. 1900 5200 10 …. 1900 5200 19)
Type Relay (voltage free contacts)
Rated voltage AC 250 V AC / 10 A max.
Rated voltage DC 30 V DC / 10 A max.
Digital inputs
Parameter Value
Number of inputs 10 (Elektronikon® Graphic controller - p.n. 1900 5200 10 …. 1900 5200 19)
Supply by controller 24 V DC
Supply protection Short circuit protected to ground
Input protection Not isolated
Analog inputs
Parameter Value
Pressure inputs 2 (Elektronikon® Graphic controller - p.n. 1900 5200 10 …. 1900 5200 19)
Temperature inputs 5 (Elektronikon® Graphic controller - p.n. 1900 5200 10 …. 1900 5200 19)
Instruction book
2920 7104 10 95