Automatic Systems TR491-TR6-GB-a YD-JMW 20/01/00 Installation TR491 2-1106GB Rev.: C p. 11/12
Fig. 6
6:1 Walkway arm
Legend:
6:1
Ö Lift up the walkway arm (6:1) manually and make sure this holds in the horizontal position.
3.5. Check-list
Before commissioning the dropping-arm tripod turnstile, proceed with the various mechanical
tests as described in the Field manual paragraph [2.1. First service at 50,000 cycles], then
electrical (proper operation of the optional readers, pictograms, etc.). In case of a mechanical
problem, please refer to the corresponding paragraph.
Check if all wires are firmly connected to their respective terminal blocks.
Check if the tripod's walkway arm (6:1) falls down when the electrical power supply is interrupted.
Check if all screws and nuts have been tightened firmly.
Inspect the inside of the turnstile to ensure no tools remain, to cause equipment failures.
Remove any foreign body from the inside of the tripod turnstile (packing, debris, etc.), and clean.
Position the hood back(4:3) and lock it. Close and lock the front doors (4:1) and (4:2).
-- The dropping-arm tripod turnstile is now operational. Although all adjustments have been
carried out in our factory, a final adjustment may be required, following transportation and installation
of the equipment. In this case, refer to the Field manual.