Chapter 2: Registration, Assignment, and Operation 11
Axon Signal Sidearm User Manual
3 sec
Operation - Mute Mode
Use Mute Mode to remove your pistol from the holster, but NOT alert Axon cameras to record.
1 Press and hold the button for 3 seconds to go from Field Mode to Mute
Mode. The LED shows a solid color and then slowly blinks when you
enter Mute Mode.
The color of the LED indicates the status of your battery.
• A green solid and blinking LED means Mute Mode is active and the
battery is good.
• A red solid and blinking LED means Mute Mode is active and the
battery is low and needs to be replaced.
The sensor automatically returns to Field Mode after you remove your
pistol from the holster or after 30 seconds elapses, whichever happens
first.
Sensor Reset
If you have an issue with the sensor, refer to the Troubleshooting section of this manual. You may
need to reset the sensor. You can reset the sensor from any mode. Follow the steps below to reset
the sensor:
25 sec
1 Press and hold the button for approximately 25 seconds. You should
see the following LED indications:
• Initially, the LED shows a solid green or red. The color indicates
battery status.
• Then, the LED blinks the color indicating battery status. The sensor
is in Mute Mode.
• Finally, the LED blinks blue. Sensor reset has started. Release the
button.
Do not continue to hold the button. Continuing to hold the button
causes the LED to turn solid red and restores the sensor back to its
original factory settings. If this accidentally occurs, connect the sensor
to the Axon Device Manager App to ensure it has the latest firmware.
See the Firmware Updates section of this manual for more information.
2 When reset is complete, the LED blinks green 3 times and the sensor
enters Test Mode. You can now calibrate the sensor. If there is no activity
for 30 seconds, the sensor returns to Low Power Mode.