4 Product description BECKHOFF Drive Technology
22 Version 2.5 AX5000
4.8 Overview of connectors/terminal points
4.8.1 X01voltage input
4.8.1.1 AX5160 and AX5172
Terminal point
Connection
L1
Phase L1
L2
Phase L2
L3
Phase L3
PE
Protective conductor
4.8.1.2 AX5190 and AX5191
Terminal point
Connection
L1
Phase L1
L2
Phase L2
L3
Phase L3
PE
Protective conductor
4.8.1.3 AX5192 and AX5193
Terminal point
Connection
L1
Phase L1
L2
Phase L2
L3
Phase L3
PE
Protective conductor
4.8.2 X07External brake resistor
Attention
Hazard to devices
Connect the PE connection of the external brake resistor at the central
grounding bar.
DANGER
Serious risk of injury through high electrical voltage!
875 V DC voltage at the RB+ and RB- terminals. Dangerous voltage may
be present at AX5160/AX5172 for 15 minutes, at AX5190/AX5191 for 30
minutes and at AX5192/AX5193 for 45 minutes
after the device is switched
off (Check voltage).
4.8.2.1 AX5160 and AX5172
Terminal point
Connection
RB +
External brake resistor +
RB -
External brake resistor -

Table of Contents

Other manuals for Beckhoff AX5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff AX5000 Series and is the answer not in the manual?

Beckhoff AX5000 Series Specifications

General IconGeneral
BrandBeckhoff
ModelAX5000 Series
CategoryServo Drives
LanguageEnglish

Related product manuals