6 TORQUE LIMITING DEVICE
6.1 Torque limiter operation
The actuator is protected by a torque limiting device in case of over-
torque.
4 Closing direction torque scale
3 Opening direction torque scale
2 Counterclockwise direction cam
1 Clockwise direction cam
The torque limiter is triggered as cams (1) or (2) trigger their
corresponding switches when rotating.
The torque limiter is fitted with 2 scale disks (3) and (4) to adjust
the torque limits for both directions. They have torque graduations
from 40 to 100% of the maximum torque deliverable by the actuator.
The torque limiter provides a maintained contact.
If the actuator stops in a position which is not the one required,
please check that:
The valve stem is clean and well lubricated.
The valve stem does not jam in the nut.
The valve stuffing box is not too tight.