M1 Mini User Manual
16 / 32
12.5 Turning the Device Off
Take off the mask and headgear, press the Start / Stop Button or click on the icon
in the LightTrip App, and the device will stop delivering air. Disconnect the power adapter from
the power outlet to power off the device.
13. Navigating the Patient Menu
13.1 Steps to Navigating the Patient Menu
13.1.1 Accessing the setup interface
Connect the power adapter properly. Turn on the device and LightTrip App for Bluetooth
connection. After the Bluetooth connection is successful, click "Settings" and "Accessories" to
enter the corresponding parameter setting interface.
13.1.2 Setting and saving parameters
In the parameter setting interface, you can set the parameters as required. After setting the
parameters, you need to save them, and the parameter setting is completed.
13.2 Options of the Patient Menu and Corresponding Descriptions
13.2.1 Treatment setting
Option
Range
Description
Ramp
Time
0 60
minutes/
Auto
In order to increase comfort and help the patient fall asleep
easily, the pressure can increase gradually, when the Ramp
feature is enabled. The ramp time during which the initial
pressure rises to the prescribed treatment pressure can be
adjusted. The numbering increases or decreases by five
minutes. The LightTrip App displays a real-time countdown
of the remaining ramp time in minutes.
Reslex
Off/1/2/3
This feature enables the device to automatically reduce the
treatment pressure when the patient exhales, so as to make
the user more comfortable. The higher the numbering is, the
more pressure the device reduces. "Off" means this feature
is disabled.
Auto
on
On/Off
If this function is turned on, the device will automatically
start delivering air under preset pressure after the patient
puts on a breathing mask and takes several deep breaths.
Click to select "On" or "Off".
Auto
off
On/Off
If this function is turned on, the device will automatically
stop delivering air and shut down after the patient takes off
the breathing mask. Click to select "On" or "Off".
Tubing
Type
22 mm/15 mm
There are two types of tubing available. Click to select "22
mm" or "15 mm".
Mask
Type
Full Face/
Nasal/
Pillow/
Other
There are three mask types available, namely Full Face
(full-face mask), Nasal (nasal mask), and Pillow (nasal pillow
mask). But the patient can choose other suitable masks as
well. When selecting masks other than the above three
types of BMC masks, the patient can identify the masks as
other.