FOR THE USER
Temperature settings
Proceed as follows to access the temperature settings for the heating on Customer
level 2:
1. Press the Heat button until Access = CUSTOMER2 is displayed.
2. Press the Menu button.
3. Press the Select button and scroll through the menus using the menu dial.
Fine-tune the heat curve
You can “break” the heat curve up or down every fi fth outdoor degree. For example,
you can make a hump in the curve at 0ºC. Navigate to menu 1.3, press Select and
turn the menu dial until 0°C is displayed in the upper left part of the menu. Press
Adjust and turn the dial to increase or decrease the return temperature. The change
must not exceed 1 - 2°C. Press Save and wait at least 24 hours prior to any further
adjustment. The purpose of breaking the curve is to be able to infl uence the heat
pump’s heat production at extra sensitive outdoor temperatures.
Room sensor infl uence
The menu is only shown for heat pumps having a room sensor installed. You use the
menu to set how much the room sensor should infl uence the heat curve. A higher
value will have a greater effect. Please note that the room sensor only fi ne-tunes the
heat curve. Consequently, it is important the basic setting of the heat curve’s slope
and fi ne-tuning are correct.
Holiday mode
The menu is only shown for heat pumps having a room sensor installed. The
holiday function gives you the possibility to choose a number of days when the
room temperature will be lowered to 15ºC (the temperature is not adjustable).
When the days have passed the heat pump returns to the normal heating setting.
Hot water production is not affected by the holiday function.
Remote control
The menu is only shown for heat pumps having a room sensor installed. In addition,
special remote control equipment is needed. This equipment is available as an
accessory. You can switch between the remote control mode and normal mode
using a telephone.
Summer disconnection
The function means the heat pump only produces hot water when the outdoor
temperature rises above the set value.
Extra functions - Customer level 2
Main menu
Indoor temperature
settings 1
Return Select
Temperature settings
Heat curve
ne-tuning 1.3
Return Select
Temperature settings
Setting of room
sensor in 1.11
Return Select
Temperature settings
Setting of holiday
function 1.12
Return Select
Temperature settings
Remote control
temperature 1.13
Return Select
Temperature settings
Setting of summer
disconnection 1.14
Return Select