24 | KTS 530 / KTS 540 / KTS 570 | Tech nical data
5.4.2 A C and effectiv e v alue measurement
(CH1 and CH2)
* )
Property Value/Range
Frequency range AC 10 Hz — 400 Hz (-3 dB)
Measurement range 200 mV — 200 V
AC precision at 100 Hz
EFF precision at ≤ 100 Hz
±2 % of measurement
value, additional
±0.5 % of measurement range
Resolution
100 µV — 100 mV
(depending on measuring range)
*)
T h e m easurin g ran g es an d ty p es of m easurem en t "U " an d " I" are
p eak -to-p eak v alues. T h is results in th e d ig ital d isp lay field bein g
g ray ed out as soon as th e d efin ed m easurin g ran g e h as been
ex ceed ed for a sh ort tim e (O v erload ).
5.4.3 Resistance measurement (CH1)
Property Value/Range
Measurement range 100 U — 1 MU
Precision up to 200 KU
±0.75 % of measurement value
additional ±0.25 % of
measurement range
Precision up to 1 MU
±2 % of reading
additional ±0.25 % of
measurement range
Resolution
0.1 U — 1000 U
(depending on measuring range)
Input resistance > 9 MU
5.4.4 Current measurement (CH1 and CH2)
sensor Measurement range
Shunt (CH1 only) ±600 mA
30 A clamp (CH1 only) ±30 A
100 A clamp ±100 A
600 A clamp ±600 A
1000 A clamp (CH1 only) ±1000 A
5.4.5 Continuity tester (CH1)
Property Value/Range
Measurement current 2 mA
Open circuit voltage 5 V
Continuity < 10 (with acoustic response)
5.4.6 Diode measurement (CH1)
Property Value/Range
Measurement current 2 mA
Open circuit voltage 5 V
Maximum diode voltage 2 V
5.5 Oscilloscope specifications
CH1 and CH2 are potential based
(Measuring input CH1(–) or measuring input
ground must be connected to the vehicle ground).
Input resistance > 900 kOhm.
Property Value/Range
Measurement range 0 — 200 V
Coupling
DC, AC,
DC(+) (only positive range is shown),
DC(-) (only negative range is shown).
Signal source
U, 30 A (CH1 only), 100 A,
600 A, 1000 A (CH1 only),
Diagnosis pins 1 to 15
(not pins 4, 5)
X -deflection 50 µs — 1 s
Trigger mode Manual, Auto-Time, Auto-Level
Trigger source CH1, CH2
Pretrigger time 0 — 80 %
Frequency range > 1 MHz (typical 5 MHz)
Memory depth per channel
50 signal curves with
512 coordinates
5.6 B luetooth Class 1
W ireless connection
KTS 540, KTS 570 to PC/L aptop
Minimum range
Workshop environment in the open
space
30 meters
If the vehicle door or window is open
and the engine is still running in the ve-
hicle interior
10 meters
R
R
en
http://www.obd2be.com/

Other manuals for Bosch KTS 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch KTS 530 and is the answer not in the manual?

Bosch KTS 530 Specifications

General IconGeneral
BrandBosch
ModelKTS 530
CategoryControl Unit
LanguageEnglish

Related product manuals