English | 19
Corrective measure: Rub the laser beam output(11) or the
reception lens(10) dry with a soft cloth
Cause: The measuring tool was moved too quickly.
Corrective measure: Move the measuring tool more slowly.
Cause: The measuring object is outside of the range of the
laser beam.
Corrective measure: Go closer to the measuring object.
Measurement Result
Measurement result unreliable
Cause: Target surface is not reflecting clearly (e.g. water,
glass)
Corrective measure: Cover the target surface
Cause: Laser beam output(11) or reception lens(10) is con-
cealed
Corrective measure: Always keep the laser beam output(11)
and the reception lens(10) clear
Measurement result implausible
Cause: Obstacle in the course of the laser beam
Corrective measure: Ensure that the laser point is fully on the
target surface
Display Unchanged
The display remains unchanged or the measuring tool
reacts unexpectedly to pressing the measuring button/
buttons
Cause: Software error
Bosch Power Tools 1 609 92A 82K | (20.12.2022)