Page #41 background imageLoading...
Page #41 background image
Cleaning and servicing en
41
16.2 Base unit
The base unit is the accessible area
at the bottom of the appliance in
which you will find the heat ex-
changer.
Opening the base unit
Requirements
¡ The appliance has cooled down
for 30 minutes.
¡ The appliance door is closed.
1. Open the maintenance flap.
If you place a cloth beneath the
maintenance flap, you can collect
the remaining water from the base
unit.
2. Open the lever for the heat ex-
changer cover.
3. Pull out the heat exchanger cover
by the handle.
Cleaning the base unit
You can remove any visible dirt in the
base unit.
1.
Open the base unit →Page41.
2. Use a soft brush to clean the heat
exchanger cover.
Make sure that you remove all dirt
from the seal.
3. Pull the insert out horizontally.