Page 74
Lift Model
Lift Weight
The following specifications are basic to the electrical/hydraulics operations. Further technical specifications
and details of components are provided in the Systems Descriptions and Troubleshooting sections
located within this manual.
L915 L915IB L916 L916IB L917 L917IB L918 L918IB L919 L919IB
356 lbs 358 lbs 375 lbs 377 lbs 384 lbs 386 lbs 366 lbs 368 lbs 387 lbs 389 lbs
Lift Specifications
Platform Unfold (Out) - Platform unfolds from fully-stowed position to floor level position
Platform Lower - Platform only (with 400 lb. load) lowers from floor level position to fully-lowered (ground
level) position
Roll Stop Unfold (Deploy) - Roll stop rotates downward from vertical position to ramp position
Roll Stop Fold (Raise) - Roll stop rotates upward from ramp position to vertical position
Platform Raise - Platform only (with 400 lb. load) raises from fully-lowered (ground level) position to floor
level position (fully raised) position
Platform Fold (In) - Platform folds from floor level position to fully-stowed position
2. A 400 pound platform load used in all Lower and Raise operations.
3. Fully charged 12 volt DC power source. Low voltage will moderately affect test results.
4. The Length of Travel dimensions reflect the Maximum Floor-to-Ground dimension for the particular lift
models specified in the Operations Cycle Time Charts. Note: The Length of Travel dimension will vary
with differing lift installation vehicle floor heights. All figures must be calculated per your particular Length
of Travel (floor-to-ground) dimension when comparing.
1. Environmental temperature of 72° F. Extremely low temperatures can moderately affect cycle time.
Operational Specifications:
The performance data contained within the Operations Cycle Time Charts on page 76 provide general
performance criteria. This information is compiled from tests conducted on standard L915 Series lift
models meeting the following constant operational specifications.
Operations Cycle Times
Operation Descriptions:
Note: Lift weights applicable for rear and front pump lift models.
The Lift Series Code: See the lift-posted Serial
No./Series No. Identification tag.
Hydraulic Pump: M268 factory-equipped with a
manual Backup Pump (hand pump).
Hydraulic Fluid: Dextron III automatic transmis-
sion fluid. Further hydraulic fluid specifications
are provided in the Systems Descriptions section.
Hydraulic Pump Pressure Relief Valve Setting:
M268 is factory set at 2100 psi. Note: See
Systems Descriptions for adjustment procedures.
Design Lifting Capacity: 800 lbs.
Pump Identification Codes: 12 volt - 30 and
24 volt - 31 (at time of publication - see lift-posted
Serial No./Series No. Identification tag if in doubt).
Power Source: 12 VDC battery with negative
ground (Standard Lift Models). Note: Special
applications powered by 24 volt system.