Troubleshooting | 12
Instruction Manual R5 RB_RC 0021 C_EN_en 23 | 32
12 Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
● Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
● Prior to any action requiring touching the machine, let the machine cool down first.
Illustration showing parts that may be involved during troubleshooting:
Description
EF Exhaust filter GB Gas ballast valve
IS Inlet screen CPL Coupling
Problem Possible Cause Remedy
The machine does not start. The motor is not supplied with
the correct voltage.
● Check the power supply.
The motor is defective. ● Replace the motor.
The coupling (CPL) is defective. ● Replace the coupling (CPL).