3
PHYSICAL DATA
UNIT SIZE SERIES 18--- 30 24--- 30 30--- 30, 50
36--- 30, 50,
60
42--- 30, 50
48--- 30, 50,
60
60--- 30, 50, 60
Operating Weight lb (kg)
127
(57.6)
133
(60.3)
146
(66.2)
152
(69.0)
193
(87.5)
216
(98.0)
250
(113.4)
Shipping Weight lb (kg)
153
(69.4)
158
(77.6)
180
(81.6)
178
(80.7)
229
(103.8)
251
(113.8)
282
(127.9)
Compressor Type Scroll
REFRIGERANT Puron (R---410A)
Indoor Control
Piston
52
Piston
57
Piston
67
Piston
70
Piston
76
Piston
80
TXV
(Puron Hard
Shutoff)
Outdoor Heating Piston # 40 46 55 57 65 65 76
Charge lb (kg)
5.16
(2.34)
5.95
(2.70)
6.40
(2.90)
6.34
(2.88)
8.88
(4.03)
10.41
(4.72)
11.00
(4.99)
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1881 2196 3167 3167 2614 3365 4046
Motor HP 1/12 1/10 1/5 1/5 1/10 1/4 1/4
Motor RPM 1100 1100 1100 1100 1100 1100 800
COND COIL
Face Area (Sq ft) 11.49 13.13 15.09 17.25 15.09 19.40 17.60
Fins per In. 25 25 20 20 20 20 20
Rows 1 1 1 1 2 2 2
Circuits 4 4 5 5 6 8 8
VALVE CONNECT. (In.) ID
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES* (In.) OD
Rated Vapor* 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8
Liquid 3/8”
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications
Unit
Nominal
Size (Btuh)
Maximum
Liquid Line
Diameters
(In. OD)
Vapor Line
Diameters
(In.) OD
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application
Long Line Application Requires Accessories
26--- 50
(7.9--- 15.2)
51--- 80
(15.5--- 24.4)
81--- 100
(24.7--- 30.5)
101--- 125
(30.8--- 38.1)
126--- 150
(38.4--- 45.7)
151--- 175
(46.0--- 50.3)
176--- 200
(53.6--- 60.0)
201--- 225
(61.3--- 68.6)
226--- 250
(68.9--- 76.2)
18,000
1 --- S t a g e
HP with
Puron
3/8
1/2 1 2 3 4 6 7 8 9 10
5/8 0 0 1 1 1 2 2 3 3
24,000
1 --- S t a g e
HP with
Puron
3/8
5/8 0 1 1 2 3 3 4 4 5
3/4 0 0 0 0 1 1 1 1 1
30,000
1 --- S t a g e
HP with
Puron
3/8
5/8 1 2 3 3 4 5 6 7 8
3/4 0 0 1 1 1 2 2 2 3
7/8 0 0 0 0 1 1 1 1 1
36,000
1 --- S t a g e
HP with
Puron
3/8
5/8 1 2 4 5 6 7 9 10 11
3/4 0 0 1 1 2 2 3 3 4
7/8 0 0 0 0 1 1 1 1 2
42,000
1 --- S t a g e
HP with
Puron
3/8
3/4 0 1 2 2 3 4 4 5 6
7/8 0 0 1 1 1 2 2 2 3
48,000
1 --- S t a g e
HP with
Puron
3/8
3/4 0 1 2 3 4 5 5 6 7
7/8 0 0 1 1 2 2 2 3 3
60,000
1 --- S t a g e
HP with
Puron
3/8
3/4 1 2 4 5 6 7 9 10 11
7/8 0 1 2 2 3 4 4 5 5
1 --- 1 / 8 0 0 0 1 1 1 1 1 1
Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Applica-
tion Guidelines