2. Route wires through large hole in mounting base. Level mounting base
against wall (for aesthetic value only—Display Module need not be leveled
for proper operation) and mark wall through 4 mounting holes. To avoid
unintended bending of wall plate plastic, use all 4 screws and anchors. See
Fig. 7.
A07165
Fig. 7 -- Backplate Mounting
3. Drill four 3/16--in. mounting holes in wall where marked. Thermidistat Con-
trol may be mounted to a standard junction box, if desired. Hole pattern on
Thermidistat Control mounting base matches junction box mounting holes.
4. Secure rear plastic mounting base to wall with 4 screws and anchors
provided. To avoid unintended bending of wall plate plastic, use all 4
screws and anchors. Make sure all wires extend through hole in mounting
base.
5. Adjust length and routing of each wire to reach proper connector block and
terminal on mounting base with 1/4--in. (6 mm) extra wire.