39
Option 30 Programmable Fan (programmable models only)
This selection allows the homeowner to program the fan selection to “Auto or
“On” fan operation for each of the program schedule periods. This selection is only
available on programmable Thermidistat Controls.
OF (off) Programmable fan is disabled and the homeowner must manually select
“Auto” or “On” for fan operation.
On Programmable fan is enabled. The homeowner can program “Auto” or “On”
fan operation along with the heat and cool setpoints for each programmed period.
When the program schedule is running, the programmed heat setpoint, cool
setpoint, and fan selection for that period will be used. If the homeowner
“overrides” the programmed fan setting by pressing the fan button, the override
selection will remain in effect until the next programmed period time.
Default is OF (off).
Option 31 Daylight Savings Time Configuration (programmable models
only)
This selection allows the installer to set the Thermidistat Control to automatically
change by one hour on the specified day, month, and week specified.
OF (off) Daylight Savings Time Function disabled.
1,2 On The first time the UP/DOWN button is pressed, the value of this selection
changes from OF (off) to 1. When 1 is displayed, the days of the week and clock
digits will be turned on. The installer will set the start date (Spring) for Daylight
Savings Time by setting the day of the week by selecting the appropriate triangle
icon next to the days of the week, the month of the year will be set in the clock
hours location (range 1--12) and the week of the month will be set in the clock
minutes location. The week of the month selections will be F, 2, 3, 4, and L for First,
2nd, 3rd, 4th, and Last. So for the first Sunday in April, the display would show
SUN, 4, F. When 2 is displayed, the installer will then choose the end date for
daylight savings time (Fall). To activate the function, the installer changes the “2”

Table of Contents

Other manuals for Carrier Performance A07048

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier Performance A07048 and is the answer not in the manual?

Carrier Performance A07048 Specifications

General IconGeneral
BrandCarrier
ModelPerformance A07048
CategoryThermostat
LanguageEnglish

Related product manuals