EasyManuals Logo
Home>Carrier>Thermostat>Performance A07048

Carrier Performance A07048 User Manual

Carrier Performance A07048
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
40
by pressing the up button and “On is displayed. The setting shall be left On to
enable the Daylight Savings Time function.
Default is On (on).
Option 32 Furnace Heat Staging Control (available only when the
Thermidistat Control is configured to operate AC or A2 equipment).
1 Thermidistat Control controls W1 output only and furnace controls the turn on
and turn off of higher stages of heat.
2 Thermidistat Control will control the W1 and O/W2/B outputs.
Default is 1.
Option 33 Single or Two--Piece Installation
This configuration allows the Thermidistat Control to compensate for the amount of
heat generated by the Thermidistat Control electronics to allow more accurate
sensing of the temperature sensor. The amount of heat compensation will be
different between single installation and two--piece installation.
Range: 1P or 2P
1P The installation is single piece.
2P The installation is two separate pieces.
Default is 2P.

Table of Contents

Other manuals for Carrier Performance A07048

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier Performance A07048 and is the answer not in the manual?

Carrier Performance A07048 Specifications

General IconGeneral
BrandCarrier
ModelPerformance A07048
CategoryThermostat
LanguageEnglish

Related product manuals