Using the Setup Wizard
k Using Setup Wizard to Configure a PhotoGate Setup
Connection of a Vernier PhotoGate requires configuration of setup parameters that are
slightly different from parameters for other types of sensors.
• To configure a setup for PhotoGate alone
1. Perform the first two steps of the procedure under “To configure an EA-200 setup using
Setup Wizard” on page ε-2.
2. On the “Select Sensor” screen, select [VERNIER] - [Photogate] - [Gate].
This displays a screen where you specify whether PhotoGate is connected to the CH1
or SONIC channel.
3. Press 1 to specify CH1 or 2 to specify SONIC.
This causes a “Gate Status” screen to appear.
“Open” means the photo path is not blocked, while “Close” means the photo path is
blocked.
The gate status defines what PhotoGate status should cause timing to start, and what
status should cause timing to stop.
Open-Open ..............Timing starts when the gate opens, and continues until it closes
and then opens again.
Open-Close..............Timing starts when the gate opens, and continues until it closes.
Close-Open..............Timing starts when the gate closes, and continues until it opens.
Close-Close .............Timing starts when the gate closes, and continues until it opens
and then closes again.
4. Use function keys 1 through 4 to select a Gate Status setting.
Selecting a gate status causes a screen for specifying the number of samples to
appear.
5. Input an integer in the range of 1 to 255 to specify the number of samples.
6. Perform step 10 under “To configure an EA-200 setup using Setup Wizard” on page
ε-2
to finalize the procedure.
• To configure a setup for PhotoGate and Smart Pulley
1. Perform the first two steps of the procedure under “To configure an EA-200 setup using
Setup Wizard” on page
ε-2.
2. On the “Select Sensor” screen, select [VERNIER] - [Photogate] - [Pulley].
This causes an “Input Distance(m)” screen to appear.
The distance you specify here is the distance the weight travels after it is released.
Input a value in the range of 0.1 to 4 to specify the distance in meters.
3. Perform step 10 under “To configure an EA-200 setup using Setup Wizard” on page
ε-2
to finalize the procedure.

Table of Contents

Other manuals for Casio FX-CG10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio FX-CG10 and is the answer not in the manual?

Casio FX-CG10 Specifications

General IconGeneral
BrandCasio
ModelFX-CG10
CategoryCalculator
LanguageEnglish

Related product manuals