EasyManuals Logo
Home>Casio>Watch>G-Shock QW-3403

Casio G-Shock QW-3403 User Manual

Casio G-Shock QW-3403
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
– �� –��
QW-3403
7. TESTING: MODULE QW-3403
7-1. MEASURING CURRENT CONSUMPTION
�) Apply a voltage of 3.0 V.
2) Perform AC.
3) Wait two seconds.
4) Measure the current consumption.
The current consumption should be 2.21 μA or less.
7-2. CHECKING THE MODEL
CHECKING THE LCD SEGMENTS
Timekeeping mode
ACCURACY CHECKING
MODEL CHECKING
++
Except for
Except
for
Any Button
Except for
All litLight alternates
Except
for
TIME ZONE CHECKING
Note:
The watch returns to the Timekeeping mode when it is left untouched for 1 to 2 hours after the last
button operation. (Auto Return)
The watch returns to the Timekeeping mode when the alarm goes off.
The Auto Light function is disabled when the watch enters the test mode.
7-3. ACCURACY CHECKING
�) While in the Timekeeping mode, hold down
A
and press
D
and
C
at the
same time.
2) Then all the segments are displayed and the LCD drive signals are changed
to the test signals so that you can check the accuracy with a quartz timer.
Measure the accuracy value in the following conditions.
SENSOR GATE TIME
LCD 2 seconds
3) Exit the Accuracy Checking mode.
Press
D
to go to Model checking mode.
Press any button except for
D
to return to the Timekeeping mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio G-Shock QW-3403 and is the answer not in the manual?

Casio G-Shock QW-3403 Specifications

General IconGeneral
BrandCasio
ModelG-Shock QW-3403
CategoryWatch
LanguageEnglish

Related product manuals