Menus and Functions continued
4 COUNTERS contains 5 counter functions
• ^STROKE S000000 keeps a running total of the strokes count. The strokes counter will
increment every stroke of the press. It can be used with the batch to
stop the press when the required number of parts have been made.
• ^BATCH> B000000 BATCH count programming. Press > then use the number keys to pro-
gram the number of parts/strokes. When the strokes count is equal to
the Batch, the counter output will de-energize and a Batch Count
message will be displayed.
• ^ZeroStrks (ENT) Zeros the Strokes count. Press enter to zero the strokes count
• ^THITS T00000000 keeps count of the Total HITS . Counts every stroke of the press. This
can be an excellent tool to schedule press mantainance.
• ^Zero TOTAL(ENT) Zero the TOTAL hits counter. Press enter to zero the total hits count.
5 SUPERVISOR contains one function to enable or disable programming
• SETUP>DISABLED
OR displays whether programming is enabled or disable. Press>
SETUP>ENABLED then use the arrow keys to enable or to toggle to disable.
See programming quick reference guide.
5 5