4 4
MENUS and FUNCTIONS
There are 5 menus. Four of them have other functions.
1 POS/TACH shows the current real time position and speed of the press in strokes per minute.
There are no additional functions under this menu.
2 INITIAL contains 4 functions. These are only set when the control is initially installed.
• ^ZERO SET (ENT) zeroes the resolver to the mechanical position of the press. Press enter
to zero the resolver position.
• ^MDET >L000-H999 Motion DETect sets the low and high SPM limits. Press >, then use the
arrow keys to program the low and high SPM limits for the press.
Press ENTER to save. If during normal operation the press goes below
or above the limits a motion fault will occur and the fault output will
de-energize until reset.
• ^MDLY >D999 Motion DeLaY sets the delay before a low motion fault will occur so
that the press can get up to speed. Press >, then use the arrow keys to
adjust the setting in milliseconds. Press enter to save.
• ^TSTOP >A310 Top STOP sets the Angle that the Fault/Batch output will open when a
batch count is reached. Press >, then use the arrow keys to adjust the
setting in degrees. Press enter to save.
3 LIMIT SWITCHES contains 5 functions.
• ^LS1 >F000-T000 Limit Switch 1 programming output ON at (From degrees - To degrees)
Press > then use the arrow keys to program a From-To window. Press
enter to save.
• ^LS2 >F000-T000 Limit Switch 2 programming output ON at (From degrees - To degrees)
Press > then use the arrow keys to program a From-To window. Press
enter to save.
• ^LS3 >F000-T000 Limit Switch 3 programming output ON at (From degrees - To degrees)
Press > then use the arrow keys to program a From-To window. Press
enter to save.
• ^LS4 >F000-T000 Limit Switch 4 programming output ON at (From degrees - To degrees)
Press > then use the arrow keys to program a From-To window. Press
enter to save.
^SCOMP >S000-A000 Speed COMPensation adds the programmed angle A
*
(SPM/100) to
the limit switch settings. Compensation does not begin until the press
SPM (strokes per minute) is equal to or greater than the programmed
speed S. (See speed compensation, optional)