EasyManuals Logo
Home>Cisco>Network Router>ASR 1002-HX

Cisco ASR 1002-HX Removing And Replacing

Cisco ASR 1002-HX
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
It is not required to place the chassis power switch in the Standby position if you want to hot-swap
a single power supply.
Note
Step 3 Remove the plastic cover from the terminal block.
Step 4 Unscrew the two terminal block screws on the unit and remove the wires from the power supply.
Step 5 Press the power supply retaining latch towards the pull handle, grasp the handle with one hand, and pull the
power supply out of the slot while supporting the weight of the power supply with the other hand.
Installing DC Input Power Supplies
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Do not install the power supplies with the chassis cover off.
Note
This section describes how to install the DC power supply input power leads to the DC input power supply.
Before you begin, read these important notices:
The color coding of the DC input power supply leads depends on the color coding of the DC power
source at your site. Ensure that the lead color coding you choose for the DC input power supply matches
the lead color coding used at the DC power source and verify that the power source is connected to the
negative (–) terminal and to the positive (+) terminal on the power supply.
Ensure that the chassis ground is connected on the chassis before you begin installing the DC power
supply. Follow the steps provided in the "Chassis Ground Connection" section.
For DC input power cables, the wire gauge is based on the National Electrical Code (NEC) and local
codes for 26 amp service at nominal DC input voltage (–40/–72 VDC). One pair of cable leads, source
DC (–) and source DC return (+), are required for each power distribution unit (PDU). These cables are
available from any commercial cable vendor. All DC input power cables for the chassis should be 10
gauge wire and cable lengths should match within 10 percent of deviation.
Each DC input power cable is terminated at the PDU by a cable lug, as shown in the following figure.
DC input power cables must be connected to the PDU terminal studs in the proper positive (+) and negative
(–) polarity. In some cases, the DC cable leads are labeled, which is a relatively safe indication of the polarity.
However, you must verify the polarity by measuring the voltage between the DC cable leads. When making
the measurement, the positive (+) lead and the negative (–) lead must always match the (+) and (–) labels on
the power distribution unit.
Note
Removing and Replacing FRUs
6
Removing and Replacing FRUs
Installing DC Input Power Supplies

Other manuals for Cisco ASR 1002-HX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002-HX and is the answer not in the manual?

Cisco ASR 1002-HX Specifications

General IconGeneral
BrandCisco
ModelASR 1002-HX
CategoryNetwork Router
LanguageEnglish

Related product manuals