Figure 15 Cisco ASR 1002-F Router DC Power Supply
Step 2 Ensure that the negative and positive leads are disconnected from the site power source.
Step 3 Using a wire stripper, strip approximately 0.55 inch (14 mm) from the positive, negative, and ground leads.
Step 4 Insert the stripped end of the ground lead all the way into the ground lead receptacle on the DC-input power supply,
and tighten the receptacle screw using a 3.5 mm flat-blade screwdriver.
Step 5 Insert the stripped end of the positive lead all the way into the positive lead receptacle and tighten the receptacle screw
using the same 3.5 mm flat-blade screwdriver. Repeat this step for the negative lead.
Note Make sure the entire stripped end of each lead is inserted all the way into its receptacle. If any exposed wire at the
stripped end of a lead is visible after inserting the lead into its receptacle, remove the lead from the receptacle, use
the wire stripper to cut the stripped end of the lead, and repeat Step 3 through Step 5.
Step 6 After tightening the receptacle screw for the ground, positive, and negative DC-input leads, use a cable tie to secure the
three leads to the power supply faceplate.
Caution When securing the earth ground, positive, and negative DC-input leads to the power supply faceplate, leave a
service loop in the ground lead, (see Figure 15, item 1), to ensure that the ground lead is the last lead to disconnect
from the power supply if a great deal of strain is placed on all three leads.
Step 7 Connect the ground, positive, and negative leads to the power source.
Step 8 Turn on the branch source breaker.
Step 9 Place the Standby switch in the On (|) position.
This completes the procedure for connecting DC-input power.
1
Earth ground lead service loop area
3
DC power negative lead
2
DC power positive lead
4
Power supply Standby switch
OUTP
UT INPUT
FAIL
OK OK
FAN
-48V/-6
0V
16A
Th
i
s un
it m
ig
h
t
h
av
e
more tha
n
one power supply connection.
A
ll
con
n
e
ctions m
u
st
be rem
o
v
ed
to
d
e-
e
nergi
ze the unit.
3
1
2
280290
4

Other manuals for Cisco ASR1002 - ASR 1002 Router

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR1002 - ASR 1002 Router and is the answer not in the manual?

Cisco ASR1002 - ASR 1002 Router Specifications

General IconGeneral
BrandCisco
ModelASR1002 - ASR 1002 Router
CategoryNetwork Router
LanguageEnglish

Related product manuals