20
Verify Power Supply Operation
Follow this procedure to verify the power supplies are operating correctly.
Step 1 Check that the power supply LEDs are illuminated as follows:
–
INPUT OK LED is green.
–
FAN OK LED is green.
–
OUTPUT FAILED LED is not illuminated.
Step 2 To ensure that the power supply is running, enter the show platform command. This output sample is from a
Cisco ASR 1002-F Router.
#show platform
Chassis type: ASR1002-F
The following is a sample output display:
Note If the LEDs indicate a power problem or the power supply state shows “ps,fail”, then contact a customer service
representative for assistance or additional instructions.
Start the Cisco ASR 1002-F Router
Check the following conditions before you start the Cisco ASR 1002-F Router:
• The Cisco ASR 1002-F Router has one slot for the Cisco ASR1002-SIP10-F. Make certain that the SPA is firmly seated in
its subslot and its captive installation screws are securely tightened.
Note The ASR 1002-F Router has only one half-height removable SPA.
• The integrated Cisco ASR1002-ESP-F forwarding processor in the Cisco ASR 1002-F Router is secured and its captive
screws are securely tightened.
• All network interface cables are connected.
• The console terminal is turned on.
Slot Type State Insert Time
1 ASR1000-SIP10 ok 00:03:19
1/1 SPA-8X1GE-V2 ok 00:02:23
2 ASR1000-SIP10 ok 00:03:19
2/0 SPA-1X10GE-L-V2 ok 00:02:22
2/1 SPA-8X1GE-V2 ok 00:02:17
R0 ASR1000-RP1 ok,active 00:03:19
F0 ASR1000-ESP10 ok,active 00:03:19
P0 ASR1002-PWR-AC ok 00:02:50
P1 ASR1002-PWR-AC ps, fail 00:02:50
Slot CPLD Version Firmware
Version
1 07091401 12.2(33r)XN2
2 07091401 12.2(33r)XN2
R0 08060301 12.2(0:0)
F0 08041102 12.2(33r)XN2