Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
CLEANING THE FLUE
Access for cleaning the flue should be incorporated in the system other than
through the appliance (e.g. a soot door or access through a register plate).
Purpose-made soot doors and inspection lengths are available from the
Clarke range.
Ensure that the whole length of the flue can be reached from the soot door.
FUME EMISSIONS
To avoid chimney problems, your fire should not be burnt slowly for longer than
12 hours without a period of fast burning.
Properly installed and operated, this stove will not emit fumes although
occasional fumes from de-ashing and refuelling may occur. Persistent fume
emission must not be tolerated and if fume emission persists, the following
immediate action should be taken:-
1. Open doors and windows to ventilate room.
2. Let the fire out, or eject and safely dispose of fuel from the stove.
3. Check for flue chimney blockage and clean if required.
4. Do not attempt to re-light the fire until the cause has been identified and
corrected.
If necessary, seek professional advice.
IMPORTANT: Never fit an extractor fan in the same room as this stove.