Troubleshooting Guide,
SW version IGS-NT-3.1.0, IM-NT-3.1.0, ©ComAp August 2018 25
IGS-NT Troubleshooting Guide.pdf
IS-NT
InteliSys New technology gen-set controller
IS-NT-BB
InteliSys New Technology Basic Box (without display)
KWP2000
Key Word Protocol of Scania S6 unit (for engine diagnostics)
LAI
Logical Analog Inputs (card in GenConfig which is used to assign source signal to
controller Logical Analog Input functions, e.g. Oil press)
LBI
Logical Binary Inputs (card in GenConfig which is used to assign source signal to
controller Logical Binary Input functions, e.g. Sys Start/Stop)
LS
Load Sharing - analog load sharing line to interconnect gen-sets on site (for island
parallel or mains parallel operation of multiple gen-sets); IG/IS/IM-NT controllers
use digital Load Sharing via the CAN2 bus
LSM
Load Sharing Module
LT
Option for Low Temperature modification (display equipped with heating foil)
MCB
Mains Circuit Breaker
MGCB
Master Generator Circuit Breaker (sometimes used with multiple gen-sets in island
parallel or mains parallel operation)
MINT
Multiple application with INTernal control loops - for multiple gen-sets in island
parallel or mains parallel operation; Load Sharing and VAr Sharing controlled
internally; PMS available
MP
Mains protection
MultIslOp
Multiple Island Operation (MCB is opened, GCBs are closed)
MultParOp
Multiple Parallel Operation (MCB is closed, GCBs are closed)
NPU
Mains protection relay (voltage, frequency, vector shift protections)
OC
Occurrence Count (number of fault occurrances transmitted in diagnostic frame
from ECU)
OfL
Off load - protection type (see application manual for details)
PF
Power Factor
PGN
Parameter Group Number (refer to SAE J1939-71)
PMS
Power Management System - ensures optimization of running gen-sets on sites
with multiple gen-sets; based on kW/kVA spinning reserve or on relative (%) load;
no-master system ensures high reliability
Reverse synchronisation
Synchronisation of loaded genset to mains (MCB closing process)
RTC
Real Time Clock
SG
Speed Governor
SHAIN
Shared (virtual) Analog INput module
SHAOUT
Shared (virtual) Analog OUTput module
SHBIN
SHared (virtual) Binary INput module
SHBOUT
SHared (virtual) Binary OUTput module
Soft load
Generator soft loading according to Load ramp loop setting
Soft unload
Generator soft unloading according to Load ramp loop setting
SPI
Single Parallel Island application - for single gen-sets in parallel with mains or in
island operation; suitable for CHP applications; no MCB control
SPM
Single Prime Mover application - for single gen-sets without mains
SPN
Suspect Parameter Number (refer to SAE J1939-71)
SPtM
Single Parallel to Mains application - for single gen-sets in parallel with mains or in
island operation, with AMF support; both MCB and GCB controlled
SSB
Single Stand-By application - for single gen-sets with mains and break transfer to
mains
VPIO
Virtual periphery I/O module internal “SW wires” linking binary outputs to inputs
VS
VAr Sharing - ensures VAr sharing between gen-sets on site via the CAN2 bus (for
island parallel or mains parallel operation of multiple gen-sets)
VT
Voltage Transformer
#
Setting of setpoints (with this character in front of them) is shared between

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliSys NT and is the answer not in the manual?

ComAp InteliSys NT Specifications

General IconGeneral
BrandComAp
ModelInteliSys NT
CategoryController
LanguageEnglish

Related product manuals