EasyManuals Logo

D-Link DES-1008E User Manual

D-Link DES-1008E
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
ENGLISH
5
• Tohelpavoiddamagingyoursystem,besurethevoltageselectionswitch(ifprovided)onthepowersupplyissettomatchthe
power available at your location:
– 115volts(V)/60hertz(Hz)inmostofNorthandSouthAmericaandsomeFarEasterncountriessuchasSouthKoreaandTaiwan.
100 V/50 Hz in eastern Japan and 100 V/60 Hz in western Japan.
230 V/50 Hz in most of Europe, the Middle East, and the Far East.
• Alsobesurethatattacheddevicesareelectricallyratedtooperatewiththepoweravailableinyourlocation.
• Useonlyapprovedpowercable(s).IfyouhavenotbeenprovidedwithapowercableforyoursystemorforanyAC-poweredoption
intended for your system, purchase a power cable that is approved for use in your country. The power cable must be rated for the
product and for the voltage and current marked on the products electrical ratings label. The voltage and current rating of the
cable should be greater than the ratings marked on the product.
• Tohelppreventanelectricshock,plugthesystemandperipheralpowercablesintoproperlygroundedelectricaloutlets.These
cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding
prong from a cable. If you must use an extension cable, use a 3-wire cable with properly grounded plugs.
• Observeextensioncableandpowerstripratings.Makesurethatthetotalampereratingofallproductspluggedintotheextension
cable or power strip does not exceed 80 percent of the ampere ratings limit for the extension cable or power strip.
• Tohelpprotectyoursystemfromsudden,transientincreases and decreasesinelectrical power, use asurgesuppressor,line
conditioner, or uninterruptible power supply (UPS).
• Positionsystemcablesandpowercablescarefully;routecablessothattheycannotbesteppedonortrippedover.Besurethat
nothing rests on any cables.
• Donotmodifypowercablesorplugs.Consultalicensedelectricianoryourpowercompanyforsitemodications.Alwaysfollow
your local/national wiring rules.
• Whenconnectingordisconnectingpowertohot-pluggablepowersupplies,ifoeredwithyoursystem,observethefollowing
guidelines:
Install the power supply before connecting the power cable to the power supply.
– Unplug the power cable before removing the power supply.
– If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power
supplies.

Other manuals for D-Link DES-1008E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DES-1008E and is the answer not in the manual?

D-Link DES-1008E Specifications

Data Transfer IconData Transfer
switching fabric1.6 Gbps
data transfer rate (Ethernet, half duplex)10 Mbps
data transfer rate (Ethernet, full duplex)20 Mbps
data transfer rate (Fast Ethernet, half duplex)100 Mbps
data transfer rate (Fast Ethernet, full duplex)200 Mbps
Power IconPower
DC input5V/1.2A
power consumption (standby, DC input)0.6 watts
power consumption (standby, AC input)1.4 watts
power consumption (maximum, DC input)3.3 watts
power consumption (maximum, AC input)5.2 watts
Operating Environment IconOperating Environment
operating temperature32 to 122 ˚F (0 to 50 ˚c)
storage temperature14 to 158 ˚F (-10 to 70 ˚c)
operating humidity10% to 90% RH Non-Condensing
storage humidity5% to 90% RH Non-Condensing
Heat Dissipation IconHeat Dissipation
heat dissipation (standby, AC input)4.774 BTU/h
heat dissipation (maximum, AC input)17.732 BTU/h
Weight and Dimensions IconWeight and Dimensions
device dimensions (W x D x H)6.5” x 4.4” x 1.5” (164.5 x 111.5 x 36.0 mm)

Related product manuals