EDUS121503A Options for Indoor Unit
Options 645
4
3. Options for Indoor Unit
3.1 <KDT25N32, KDT25N50> Insulation Kit for High Humidity
380
When moving the unit at or after opening, hold the unit by the hanger brackets.
Do not apply force to the refrigerant piping, drain piping or flange parts.
Side plate (right)
Slit
Slit
Slit
B
C
240
207
Slit
1104
A
904
KDT25N63
Kit name
KDT25N50
420
207
Score
KDT25N63
Kit name
KDT25N50
1100
A
900
Hanger brackets (right)
90
Slit
KDT25N50, KDT25N63 model only
90
380
390
How to attach
Score
Kit name A
1021
821
KDT25N63
KDT25N50
3
<Procedure> Stick the insulations carefully according to the following procedures
and do not make a gap between the adjacent thermal insulations.
(1) Stick the top plate insulation T-1
,
T-2 to the indoor unit top plate.
(2) Cut off the side plate insulation
S-1
following the score.(See the right figure)
(3) Stick the side plate insulation
S-1
to the indoor unit right side plate.
(4) Stick the side plate insulation
S-1
to the indoor unit left side plate
without cutting off the area surrounded by the score.
(5) Stick the side plate insulation
S-2
to the indoor unit left side plate.
(6) Stick the bottom plate insulation
B-1
to the indoor unit bottom plate.
(7) Stick the chamber cover insulation
C-1
to the indoor unit chamber cover.
(8) Stick the hanger (left) insulation H-2 and the hanger (right) insulation
H-1
to the left and right hangers respectively.
(See the right figure for the sticking reference.)
Slit
KDT25N63
Kit name A
KDT25N50 900
1100
240
ARROW VIEW A
200
Slit
390
Designation
Side plate insulation S-1
KDT25N32
(mm)
1 pc.
(mm)
When the Installation box for adapter PCB(KRP1BA101)is used together, mount this kit before Installation box.
Bottom plate insulation
B-1
Top plate insulation
T- 2
1 pc.
Details of parts
Hanger (right) insulation
H-1
( This instruction )
VRV model only
Number of
pieces
Designation
Hanger (left) insulation
H-2
Designation
700
Number of
pieces
Cut off the area shown with oblique lines and throw it away.
Shape
(mm)
621
Chamber cover insulation
C-1
A
KDT25N32
DETAIL B
700
It is recommended to mount this kit before installing the indoor unit.
KDT25N32
Hanger bracket (left)
2 pcs.
Shape
1 pc.
Shape
VRV and Room Air conditioners
1 pc.
(mm)
Side plate (left)
(mm)
(mm)
1 pc. 1 pc.
Installation manual
Caution
This kit can be installed to the Ceiling mounted Built-in Type Air Conditioners.<Slim duct type>
704
1 pc.
Top plate insulation
T- 1
(mm)
Side plate insulation S-2
1 pc.
Sticking
reference
Number of
pieces
KDT25N32
DETAIL C
(mm)
1
5
7
2
6
8
9
A
A
4
A
A
C-1
S-1
H-1
H-2 H-1
B-1
S-2
H-2
S-1
T- 2
T- 1
«»
Kit name
KDT25N32 KDT25N50
CDXS15/18LVJU
FDXS09/12LVJU
KDT25N63
Combination table
C: 3P131323-1E

Table of Contents

Other manuals for Daikin 2MXS-N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 2MXS-N Series and is the answer not in the manual?

Daikin 2MXS-N Series Specifications

General IconGeneral
BrandDaikin
Model2MXS-N Series
CategoryHeat Pump
LanguageEnglish

Related product manuals