EDUS121503A Dimensions
Multi-Split Type Air Conditioners 2/3/4MXS-N Series 73
1
4. Dimensions
4.1 Indoor Unit
CTXG09/12QVJUW(S)
CTXG18QVJUW(S)
REAR REAR
1-3/16 (30) MIN
1-15/16 (50) MIN
1-15/16 (50) MIN
9-13/16 (250) MIN13-3/4 (350) MIN
19-11/16 (500) MIN
BOTTOMBOTTOM
FLAPS
φ11/16 (18)
φ5/8 (16)
39-5/16 (998)
26-9/16 (674.5)
2-5/16 (59)
7/8 (21.5)
UP/DOWN (AUTOMATIC)
COOLING, DRY HEATING FAN
25˚
30˚
30˚
10-5/8 (270.5)
7-7/16 (189)
50˚
50˚
65˚
35˚
35˚
(ARC466A36)
39-5/16 (998)
GENERAL RATING
NAME PLATE
11-15/16 (303)
SERVICE COVER FIXED
SCREW (ON FRONT GRILLE)
NOTE) 1.THE MARK (→) SHOWS PIPING DIRECTION.
LEFT
←
↑↑
OPERATING STATE:
1) OFF
TERMINAL BLOCK
WITH GROUND TERMINAL
(INSIDE)
INCLUDING
MOUNTING PLATE
8-3/8 (212)
8-7/16 (214)
2) ON
↓↓
INTELLIGENT
EYE SENSOR
MULTI-MONITOR LAMP
TIMER LAMP
FRONT GRILLE FIXED SCREWS
(INSIDE PANEL)
INTELLIGENT
EYE LAMP
INDOOR UNIT ON/OFF SWITCH
ROOM TEMPERATURE
THERMISTOR (INNER)
SIGNAL RECEIVER
SIGNAL TRANSMITTER
UP AND DOWN WIND
DIRECTION CONTROL BLADE
MOVABLE RANGE
11/16 (18)
9-3/8 (238)
WIRELESS REMOTE CONTROLLER
BLADE ANGLE
LEFT/RIGHT
(AUTOMATIC)
REQUIRED SPACE
FOR INSTALLATION
AIRFLOW (INDOOR)
(SPACE FOR
OPERATION)
(SPACE FOR
RECEIVING)
(SPACE FOR
RECEIVING)
(SPACE FOR
OPERATION)
(SPACE FOR
PERFORMANCE)
(SPACE FOR
RECEIVING)
DRAIN HOSE CONNECTING PART
GAS PIPE φ3/8 (9.5) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 13-3/4 (350))
LIQUID PIPE φ1/4 (6.4) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/4 (400))
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS APPROX. 18-5/16 (465)
13/16 (20)
BACK SIDE VIEW
7-7/8 (200)
5-15/16 (151)
5-9/16 (142)
STANDARD LOCATIONS OF WALL HOLES
WALL HOLE
φ2-9/16 (65)
WALL HOLE
φ2-9/16 (65)
11-15/16 (303)
1-15/16 (49)
1-15/16 (49)
13/16 (20)
C: 3D105568
AIRFLOW (INDOOR)
39-5/16 (998)
REAR
REAR
1-3/16 (30) MIN
11-15/16 (303)
1-15/16 (50) MIN
1-15/16 (50) MIN
8-3/8 (212)
8-7/16 (214)
13-3/4 (350) MIN
9-13/16 (250) MIN
2) ON
19-11/16 (500) MIN
BOTTOM
11/16 (18)
BOTTOM
9-3/8 (238)
FLAPS
φ11/16 (18)
φ5/8 (16)
39-5/16 (998)
26-9/16 (674.5)
7-7/8 (200)
2-5/16 (59) 7/8 (21.5)
13/16 (20)
13/16 (20)
UP/DOWN (AUTOMATIC)
COOLING, DRY HEATING FAN
1-15/16 (49)
25˚
30˚
1-15/16 (49)
11-15/16 (303)
30˚
10-5/8 (270.5)
7-7/16 (189)
50˚
50˚
65˚
5-15/16 (151)
5-9/16 (142)
35˚
35˚
(ARC466A36)
NOTE) 1. THE MARK (→) SHOWS PIPING DIRECTION.
LEFT
←
↑
↑
↓↓
GENERAL RATING
NAME PLATE
SERVICE COVER FIXED
SCREW (ON FRONT GRILLE)
FRONT GRILLE FIXED SCREWS
(INSIDE PANEL)
INTELLIGENT
EYE SENSOR
MULTI-MONITOR LAMP
TIMER LAMP
INTELLIGENT
EYE LAMP
INDOOR UNIT ON/OFF SWITCH
ROOM TEMPERATURE
THERMISTOR (INNER)
SIGNAL RECEIVER
SIGNAL TRANSMITTER
WIRELESS REMOTE CONTROLLER
BLADE ANGLE
LEFT/RIGHT
(AUTOMATIC)
WALL HOLE
φ2-9/16 (65)
WALL HOLE
φ2-9/16 (65)
STANDARD LOCATIONS OF WALL HOLES
BACK SIDE VIEW
OPERATING STATE:
1) OFF
TERMINAL BLOCK
WITH GROUND
TERMINAL (INSIDE)
INCLUDING
MOUNTING PLATE
REQUIRED SPACE
FOR INSTALLATION
UP AND DOWN WIND
DIRECTION CONTROL BLADE
MOVABLE RANGE
(SPACE FOR
OPERATION)
(SPACE FOR
RECEIVING)
(SPACE FOR
RECEIVING)
(SPACE FOR
OPERATION)
(SPACE FOR
PERFORMANCE)
(SPACE FOR
RECEIVING)
GAS PIPE φ1/2 (12.7) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 13-3/4 (350))
LIQUID PIPE φ1/4 (6.4) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/4 (400))
DRAIN HOSE CONNECTING PART
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS APPROX. 18-5/16 (465)
C: 3D105569